Technical data

CA01305001Z-EN www.eaton.com
12 IZMX circuit-breakers, INX switch-disconnectors
IZMX circuit-breakers, INX switch-disconnectors
IZMX circuit-breakers, I NX switch-disconnectors
Space-saving circuit-breakers with useful accessories
Eaton Introduces Series NRX!
The new NRX series from Eaton is a
new series of air circuit-breakers with
an extensive range of accessories.
The new range provides users with
two compact frame sizes up to 4000A,
modular design, common accessories,
easy to integrate communications and
a full range of trip units including the
new powerful high end 1150 Digitrip
trip unit with a full color LCD display.
The innovative concept of the IZMX16
makes it possible to install two with-
drawable circuit-breakers in a 600 mm
wide section. This enables more eco-
nomical section design and also saves
operating space. The compact modu-
lar design of the IZMX40 offers cus-
tomers a full range of high
performance ratings in a single frame
size simplifying the integration pro-
cess into panel boards and switch
boards. Series NRX, a new generation
and new standard in circuit protection.
Applications
The circuit breakers can be used in
four main application areas depending
on the type of equipment to be protect-
ed:
System protection
Motor protection
Transformer protection
Generator protection
These key applications make different
demands on the switches, which are
met with a range of control units.
Switches with closing release
They are particularly suitable for syn-
chronization tasks.
Coupler switches
In addition to the circuit-breakers,
switch-disconnectors are also avail-
able. These are used, for example, as
coupler switches between different
power supplies. The switch-discon-
nectors are used as coupler switches
for different sections of a network in
conjunction with our automatic net-
work switching device.
Modular Design, Common
Accessories
The retrofitting of accessories is made
considerably easy thanks to the effi-
cient “plug & work” technology. Ac-
cessory drawers and snap-fit
mechanisms make it possible to fit the
latest accessories with virtually no
tools. This flexibility allows you to re-
spond easily to changing requirements
within your system. Most accessories
for Series NRX are common to both the
compact and standard frame sizes.
Standard scope of delivery
With the new Series NRX range, you
select a basic device that is already
fitted with an electronic release.
The standard mounting for both
frames is on a horizontal mounting
plate or on horizontal traverses in
the switching cabinet. The IZMX16
can also be fastened to vertical
mounting plates.
With four-pole devices, the neutral
conductor is arranged on the left
(front view).
The neutral conductor can be load-
ed 100% like the phase conductors.
The circuit-breakers are provided
with a standard mechanical reclos-
ing lockout. After an overload trip,
the fault is usually examined first.
After the fault is identified and recti-
fied, the mechanical reclosing lock-
out is reset by pressing the red
mechanical trip indicator on the
front of the circuit-breaker.
A “remote-reset” feature and an
“automatic reset” are offered as ad-
ditional ordering options. The re-
mote reset enables resetting the
breaker after an over current trip via
a control voltage. The automatic re-
set option enables the circuit break-
er to be restored to normal
operation immediately after an over
current trip (i.e. there is no mechan-
ical reclosing lockout). In these ap-
plications compulsory fault analysis
is intentionally avoided.
The number of secondary control
cable terminals depends on the ac-
cessories fitted.
If a cassette is ordered without the
basic device, this can be already fit-
ted with the maximum number of
control cable terminals. For greater
economy in large plants, the cas-
sette is also offered without control
circuit terminals so that fitting can
be carried out later at the installa-
tion or when accessories are re-
quired at a later time..
The withdrawable basic device in-
cludes the primary finger clusters
and levering-in mechanism. NOTE:
Some manufacturers mount the pri-
mary finger clusters inside the cas-
sette cell, which requiring shutdown
of the panel board for inspection
and maintenance.
2 changeover contacts are provided
as standard for ON/OFF status indi-
cation.
A coding mechanism between the
basic device and the cassette pre-
vents impermissible combinations
(“Rejection Interlock”).
The door escutcheon is always in-
cluded in the scope of delivery. With
withdrawable designs this is sup-
plied with the cassette (withrawable
unit).
On withdrawable units the circuit
breaker can be pulled out to inspect
the arc chutes. With fixed units, it is
recommended that sufficient space
is provided above the circuit break-
er to enable inspection. An addi-
tional cover is not required.
All basic devices that are provided
with universal protection (Digitrip
520M), feature a 4-digit LCD display,
and all devices provided with power
measurement protection feature a
full color LCD display.
On each circuit-breaker the inte-
grated Digitrip electronic release is
factory fitted with a sealable protec-
tive cover.
If a motor operator is ordered, the
“Spring-operated stored energy
mechanism tensioned” indicator
switch is automatically provided.
Additional benefits Series NRX
The “universal” design of the main
terminal offers maximum flexibility.
The horizontal terminal can be rotat-
ed simply at the installation so that it
can also be used as a vertical con-
nection. With withdrawable units,
additional terminal pieces can even
be dispensed with. Both the
Series NRX breaker and the cas-
sette offer an integrated flange ter-
minal to which the system busbars
can be connected directly. For this
reason, the main terminal pieces for
Series NRX are not part of the stan-
dard scope of delivery. Don’t forget
to order additionally required termi-
nal pieces if required.
Thanks to the separate mounting
position, a switching operations
counter can now be used also inde-
pendently of a motor operator.
Withdrawable unit operation: The
unit is actuated with a hand crank
supplied as a standard feature and
has a secure position in the basic
device.
External 24 V supply
The standard protection functions of
Series NRX operate independently
of an external control voltage sup-
ply. The power supply of the elec-
tronics unit, for example for
overload and short-circuit protec-
tion, is implemented via the current
transformers integrated in the cir-
cuit-breaker.
The universal and power measure-
ment release units with display can
be fed with a 24 V DC supply so that
the display function can be used
without a load. An external 24 V DC
power supply is needed if communi-
cation functions are required
CurveSelect characteristics
program
Display characteristic curves accord-
ing to specific settings and assess
their interaction effectively:
www.moeller.net/de/support