Technical data

IZMX circuit-breakers, INX switch-disconnectors
Type Code for Eaton IEC-ACB global (non-EMEA)
CA01305001Z-EN www.eaton.com
5
Position 1-8
Basic Device Selection
Position 9-11
Overcurrent
Protection
Position 12-20
Options & Accessories
Pos:
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
Type Code
Example:
R E S 8 4 0 3 W 5 2 G A B A N 4 X N D X
Options & Accessories Position 17
Postion 9-20 Trip Indicator Bell
Alarm/OTS
Secondary
Terminal Blocks
Remote Reset
Position 12 - Shunt Trip N None None Per Breaker Options
N No Shunt Trip X Trip Indicator None Per Breaker Options
A 110-127 V AC/DC Z Trip Indicator 2 Form C Per Breaker Options
R 208-240 V AC/DC M Interlock Trip Indicator None Per Breaker Options
L 24 V DC A Interlock Trip Indicator None Per Breaker Options 24 V AC
H 48 V DC B Interlock Trip Indicator None Per Breaker Options 120 V AC
S 60 V DC C Interlock Trip Indicator None Per Breaker Options 240 V AC
Y Interlock Trip Indicator 2 Form C Per Breaker Options
Position 13 - Motor Operator D Interlock Trip Indicator 2 Form C Per Breaker Options 24 V RR
M Manually Operated E Interlock Trip Indicator 2 Form C Per Breaker Options 120 V RR
B 110-125 V AC/DC F Interlock Trip Indicator 2 Form C Per Breaker Options 240 V RR
T 208-250 V AC/DC 1 None None Full-Compliment
L 24 V DC 2 Trip Indicator None Full-Compliment
H 48 V DC 3 Trip Indicator 2 Form C Full-Compliment
S 60 V DC 4 Interlock Trip Indicator No OTS Full-Compliment
J Interlock Trip Indicator No OTS Full-Compliment 24 V RR
Position 14 K Interlock Trip Indicator No OTS Full-Compliment 120 V RR
Spring Release Latch Check Switch L Interlock Trip Indicator No OTS Full-Compliment 240 V RR
S Interlock Trip Indicator 2 Form C Full-Compliment
N No Spring Release No LCS R Interlock Trip Indicator 2 Form C Full-Compliment 24 V RR
A 110-127 V AC/DC No LCS S Interlock Trip Indicator 2 Form C Full-Compliment 120 V RR
B 110-127 V AC/DC Spring Release LCS T Interlock Trip Indicator 2 Form C Full-Compliment 240 V RR
C 110-127 V AC/DC LCS Wired External
R 208-240 V AC/DC No LCS Position 18 - PadLocking, Operations Counter
S 208-240 V AC/DC Spring Release LCS N No PB Covers No Counter
T 208-240 V AC/DC LCS Wired External A No PB Covers Counter Provided
L 24 V DC No LCS B PB Covers (plastic/plastic) No Counter
P 24 V DC Spring Release LCS J PB Covers (plastic/plastic) Counter Provided
Q 24 V DC LCS Wired External K PB Covers (metal/metal) No Counter
H 48 V DC No LCS L PB Covers (metal/metal) Counter Provided
J 48 V DC Spring Release LCS 5 PB Covers (metal/metal), Safe-Off No Counter
K 48 V DC LCS Wired External 6 PB Covers (metal/metal), Safe-Off Counter Provided
1 60 V DC No LCS
2 60 V DC Spring Release LCS Position 19 - Drawout Breaker Options
3 60 V DC LCS Wired External Breaker configuration Shutters Terminal Adapters
D Drawout Breaker Shipping Alone n/a None
Position 15 - UVR / Second Shunt Trip C Drawout Breaker in Cassette None No Terminals
NNone 1 Drawout Breaker in Cassette None Vertical
A 110-125 V AC/DC UVR 2 Drawout Breaker in Cassette None Horizontal
R 220-250 V AC/DC UVR 8 Drawout Breaker in Cassette None Front Connect
L 24 V DC UVR
H 48 V DC UVR 9 Drawout Breaker in Cassette Shutters No Terminals
S 60 V DC UVR 4 Drawout Breaker in Cassette Shutters Vertical
1 110-127 V AC/DC Second Shunt Trip 5 Drawout Breaker in Cassette Shutters Horizontal
2 208-240 V AC/DC Second Shunt Trip 7 Drawout Breaker in Cassette Shutters Front Connect
4 24 V DC Second Shunt Trip
8 48 V DC Second Shunt Trip Position 19 - Fixed-Mount - Terminal Adapater Options
9 60 V DC Second Shunt Trip K None (Terminals recomended for 4000A frame)
F Vertical
Position 16 - Auxiliary Switches H Horizontal
N No Aux Switches B Front Connect
22 Form C
44 Form C Position 20
66 Form C XFuture
88 Form C
A 10 Form C
W 12 Form C