User Manual

EN 21
INSTALLATION
First, read the separate safety instructions before
installing the device!
KIV360WIT KIV254RVS / KIV354RVS
560
600
75
560
540
75
Model KIV360WIT and KIV354RVS are connected to the mains as a 2 phase
cooking group. Despite the fact that this is the most commonly used connection,
the local connection situation may still differ. Therefore always consult the
separate installation instructions! If the appliance does not work, have a
recognized installer adjust the perilex wall socket.
Kookgroep aansluiting!
2-2N 230V 50Hz
2x 16A
?
230VAC
0VAC
230VAC
N1 N2
L1 L2
230Vac
V=
Install the hob on a flat, stable and horizontal base.
Keep a free space of at least 2,5 cm around the hob.
After installation, the socket must always be accessible.
The walls and the worktop surrounding the appliance must be heat resistant up to at
least 85 ˚C. Even though the appliance itself does not get hot, the heat of the hot pan could
discolour or deform the wall.
Ensure that the power cord will not come in contact with parts that can become hot.
Do not place any inflammable or deformable objects directly beneath the hob.
This appliance must be connected to a earthed power socket.