User`s guide

HTML SET UP & DIAGNOSTIC
“TCP port number” parameter
:
Set the port number the gateway has to use.
If the Raw TCP client gateway is assigned to both serial COM ports, the
CP port numbers must be different on each port. T
“Raw server IP address” parameter
:
The raw client gateway is able to communicate with a raw server
gateway.
Assign an IP address to define the destination gateway.
nswer requests
oming from devices located on the IP network and acting like a master
17.2.2 Raw server gateway
That gateway can be used if a serial slave device has to a
c
(also called TCP client).
Select the “transparent” and then the “raw server COM1” or the
“raw server COM2” menu.
Enable the raw server gateway and set up the parameters as
lows
“RS232/485 input buffer size” parameter :
fol :
t up t
re transmitting it to the IP network.
eter :
Se he maximum length of an asynchronous string the gateway will
store befo
Page 54 User’s guide ref 9014809-03 Failsafe ring SHDSL switch
“Timeout of RS232/485 end of frame” param
Set up the delay the gateway will wait before declaring complete a string
received from the asynchronous device.