Page 38 User’s guide ref 9014809-03 Failsafe ring SHDSL switch
Setting up port 2
• Select the NTU checkbox.
• Select the “Signal power” value “Auto”.
13.3 Setting up a failsafe ring using the ETIC ring
To set up the RING master switch
• Select the “Ethernet & switching” menu and then the “failsafe ring” menu.
• Select the “failsafe ring active” checkbox.
• Select the “Ring master” checkbox.
• Click the red button “REBOOT” to restart the product.
To set up the RING master switch
• Select the “Ethernet & switching” menu and then the “failsafe ring” menu.
• Select the “failsafe ring active” checkbox.
• Click the red button “REBOOT” to restart the product.
13.4 Setting up a failsafe ring using STP
• Select the “Ethernet & switching” menu and then the “failsafe ring” menu.
• Select the “STP active” checkbox and leave the default value of the additional
parameters otherwise refer to the STP norm IEEE 802.1D .
• Click the red button “REBOOT” to restart the product.
13.5 Testing the SHDSL connection and adjusting the data rate
• Connect two XSRING to a line, check the line led (the lower led of
each SHDSL connector) blinks during the connection (45 seconds) and
then lights on permanently.
Remark : The led glitters slightly with the shdsl traffic.
• If the led blinks endlessly, it means the connection cannot be
established; select a lower data rate.