User`s guide

HTML SET UP & DIAGNOSTIC
Page 38 User’s guide ref 9014809-03 Failsafe ring SHDSL switch
Setting up port 2
Select the NTU checkbox.
Select the “Signal power” value “Auto”.
13.3 Setting up a failsafe ring using the ETIC ring
To set up the RING master switch
Select the “Ethernet & switching” menu and then the “failsafe ring” menu.
Select the “failsafe ring active” checkbox.
Select the “Ring master” checkbox.
Click the red button “REBOOT” to restart the product.
To set up the RING master switch
Select the “Ethernet & switching” menu and then the “failsafe ring” menu.
Select the “failsafe ring active” checkbox.
Click the red button “REBOOT” to restart the product.
13.4 Setting up a failsafe ring using STP
Select the “Ethernet & switching” menu and then the “failsafe ring” menu.
Select the “STP active” checkbox and leave the default value of the additional
parameters otherwise refer to the STP norm IEEE 802.1D .
Click the red button “REBOOT” to restart the product.
13.5 Testing the SHDSL connection and adjusting the data rate
Connect two XSRING to a line, check the line led (the lower led of
each SHDSL connector) blinks during the connection (45 seconds) and
then lights on permanently.
Remark : The led glitters slightly with the shdsl traffic.
If the led blinks endlessly, it means the connection cannot be
established; select a lower data rate.