User`s guide
HTML SET UP & DIAGNOSTIC
Failsafe ring SHDSL switch User’s guide ref 9014809-03 Page 29
Remark :
The SW01 and SW02 must not be left in that position during operations.
6 Recovering the factory configuration
For any reason, it may be necessary to restore the factory configuration of
the SHDSL switch.
To restore the factory configuration,
• Switch OFF the power supply.
• Press the push button on the top part of the IPL-E router and switch
ON the power supply.
• Keep the push button pressed until the Operation led turns red.
Remark : The stored configuration will be lost; the factory IP address
192.168.0.128 will be restored.
7 Restricting access to the administration server
The access to the administration server can be protected by a login and
password.
To protect access to the administration server,
• Select the “System” menu, and then the “Administration rights” menu.
8 Recovering a free access to the administration server
If the Login & or password entered to reach the administration server
have been rejected, it is possible to recover a free access to the
administration server from the LAN only, by setting SW01 ON and SW2
OFF.
Remark :
The factory IP address 192.168.0.128 will also automatically be restored
as long as SW01 will remain ON and SW2 OFF.
During normal operations SW01 and SW02 must not be left in that
position.