User`s guide

INSTALLATION
Page 16 User’s guide ref 9014809-03 Failsafe ring SHDSL switch
2 Ventilation
To avoid overheating when the ambient temperature is high, leave a 1 cm
(0.5 inch) space on each side of the product.
3 Supply voltage
The product comes with 2 separate voltage inputs, so that 2 external
power supply modules can be connected to the product. If one power
supply module fails, the XSRING will be powered by the other.
The supply voltage must be
strictly lower than 60 VDC and higher than 9 VDC for XSRING-
2400 and XSRING-2230.
strictly lower than 30 VDC and higher than 9 VDC for XSRING-
2220.
The consumption is 170 mA at 24 VDC.
4 Fuse
The product is protected with a 3A fuse located on the electronic board
near the supply voltage connectors.
!!! A replacement fuse is available on the board ; it is located over the leds.
5 Ethernet ports
The XSRING features two or four auto-sensing 10/100 Mbps MDI/MDI-X
LAN ports.