User`s guide

SET UP
Page 36 User’s guide ref 9018809-01 XSRING+ SHDSL switch
Setting up the XSRING+ number 2
Click Set up > Ethernet & switching > SHDSL ports.
Select « Enable » (port 1 or 2 or 3 or 4).
Assign one connection profile to the SHDSL port (Standard or Performance or Endurance or
TurboShort).
Select the line aggregation options
Remark : the aggregation option must be the same for the XSRING+ number 1 and the for the
XSRING+ number 2.
SHDSL page XSRING+
11.3 Step 2 : SHDSL test and set up adjustment
Connect the two XSRING+ to the lines (2 or 3 or 4 twisted pairs) .
Each line should be connected at the same position on both SHDSL switches (port 1 to port 1, port
2 to port 2 etc…).
Switch the power ON.
The connection on each line will be established 30 s latter.
The led attached to each SHDSL port reports the connection status according to the table below :
STU-C STU-R
The other XSRING+ has not been detected
(for instance when the line is not connected)
Flashing 0,1 s ON / 2 s OFF Flashing 1 s ON / 1 s OFF
The other XSRING+ has been detected Flashing 1s ON / 1s OFF Flashing 1s ON / 1s OFF
Data rate negotiation Flashing 0,3s ON / 0,3s OFF Flashing 0,3s ON / 0,3s OFF
Connected Always ON Always ON
Connected & transmitting data Flashing at high speed Flashing at high speed
Connect the PC to the SHDSL switch configured as an STU-C.
Click Diagnostic> Network status> Interface, to check the connection quality on each line.
The “SHDSL ports state” table is displayed. It reports the status of each SHDSL port.