User`s guide
SET UP
Page 34 User’s guide ref 9018809-01 XSRING+ SHDSL switch
11 Setting up a point to point connection using 2 twisted pairs
This chapter describes how to set up a connection between two XSRING+ using up to four twisted
pairs to multiply the effective data rate.
The XSRING+2XXX SHDSL switch
provides two SHDSL interfaces; using two
twisted pairs, the data rate can reach 11,4
Mb/s (5.7 Mb/s over each pair) and even
20 Mb/s (10 Mb/s over each pair) over 1
Km.
11.1 Set up steps
Step 1 : SHDSL Connection set up
That step consists in assigning a STU-C connection profile (Performance, Standard, Endurance,
Turbo-short) to each SHDSL port of the one SHDSL switch,
And to assign the STU-R profile to all the SHDSL ports of the other switch,
Step 2 : Connection test and set up adjustment.
11.2 Step 1 : SHDSL connection set up
Setting up the XSRING+ number 1
• Click Set up > Ethernet & switching > SHDSL ports.
• Select « Enable » (port 1 to 4).
• Assign the SHDSL profile « STU-R, Auto ».
• Select the line aggregation options
• Click “Save”.
XSRING+2XXX