User`s guide

Installation
Page 18 Users guide ref 9014709-01 XSLAN Shdsl switch
That cable ends with 2 wires.
The 2 wires have to be connected to the 2 wires of the line.
The wires can be inverted.
Shield :
If the cable is shielded, the shield must be connected, at one end, to the
protective earth pin available at the bottom of the product or directly to the
earth.
9 Input and output
Alarm output
1 relay output is provided to indicate an alarm.
The alarm condition can be selected using the html server.
The Default condition is :
The XSLAN is out of power or 1 or both SHDSL ports are not
connected.
The electrical characteristics of the output are :
Maximum voltage : 50 VDC
Maximum current : 500 mA
Input
That input is not isolated.
if it is opened, an SNMP trap will be sent to the SNMP server is that
function has been enabled.
1
2
4
3
3V
IN
6
5
OUT
7
8
XSLAN