User manual
CONFIGURATION
IPRS serial gateway User guide ref. 9018409-01 Page 13
RS232 RJ45 connector
(To connect to a DCE to the RS232 port)
(IPRS-1220 or IPRS-1230)
Pin Nr Circuit Function
1 DTR - 108 OUT Data terminal ready
2 TD - 103 OUT Data Emission
3 RD - 104 IN Data Reception
4 DSR - 107 IN Data set ready
5 SG - 102 - Ground
6 Not used OUT -
7 CTS - 106 IN Clear to send
8 RTS - 105 OUT Request to send
RS232 : RJ45 connector
(To connect a DTE to the RS232 port)
(IPRS-1220 or IPRS-1230)
Pin Circuit Direction Function
1 CD - 109 OUT Carrier detect
2 RD - 104 OUT
Data Reception
3 TD - 103 IN
Data Emission
4 DTR - 108 IN Data terminal ready
5 SG - 102 - Ground
6 DSR - 107 OUT Data set ready
7 RTS - 105 IN Request to send
8 CTS - 106 OUT Clear to send
DIP switches
SW 1 SW 2
Management
OFF OFF
The current IP@ of the product is the stored IP @
ON OFF
The active IP@ of the product is the factory IP@ : 192.168.0.128
No login and password are required to access to the html server.
OFF ON
The active IP@ is provided by the BOOTP or DHCP server.
ON ON
Reserved
Push-button : It enables to restore the factory profile.
To restore the factory profile, switch the power on while pressing the
push-button until the RUN light turns green.
Attention : Once the factory profile has been restored, the stored
configuration is lost.