Specification
ETi Solid State Lighting
720 Northgate Parkway, Wheeling, IL 60090 | TEL: 1.855.384.7754
E-mail: etiorders@ETiSSL.com | www.ETiSSL.com.com
All specications are subject to change without notice.
All reported values are nominal or typical values, measured under laboratory conditions @ 25
o
C (77
o
F).
Actual performance can vary slightly as a result of end-user application & environment.
ESS1005A | December 7th, 2020 | Page 4 of 6
WR Direct|Indirect Series
EZ Install Direct|Indirect Architectural Wrap Light
3,977 Direct Lumens | 2,725 Indirect Lumens | DLC | 5-yr Warranty
PHOTOMETRIC DETAILS
0° 45° 90°
0° 10° 20° 30° 40°
180° 170° 160° 150° 140°
50°
130°
60°
120°
70°
110°
80°
100°
90°
366 cd
733 cd
1099 cd
1466 cd
Indoor Candela Plot
WR-4FT-6700LM-8-40K-MV-LVD
Luminaire Data
IES File Name 56567241.IES
CCT & CRI 4000K, 80CRI minimum
Initial Delivered Lumens 6,702
Wattage 55.6W
Ecacy 120.5
Beam Angle (H x V) 50% = 101
o
x 105
o
Field Angle (H x V) 10% = 174
o
x 156
o
Zone Lumens % Luminaire
0-30
o
1120 16.7%
0-40
o
1811 27.0%
0-60
o
3087 46.1%
0-90
o
3977 59.3%
90-180
o
2725 40.7%
0-180
o
6702 100.0%
Zonal Lumen Summary
Photometric values based on tests performed
in compliance with LM-63 & LM-79
Angle 0
o
90
o
0
o
1466 1466
5
o
1458 1459
10
o
1431 1438
15
o
1388 1404
20
o
1330 1355
25
o
1256 1292
30
o
1171 1215
35
o
1073 1121
40
o
970 1016
45
o
858 900
50
o
745 786
55
o
630 676
60
o
516 572
65
o
404 485
70
o
295 485
75
o
196 342
80
o
107 279
85
o
40 219
90
o
3 70
Candlepower
Angle 0
o
90
o
90
o
3 7
95
o
11 59
100
o
26 133
105
o
48 207
110
o
75 326
115
o
101 532
120
o
126 722
125
o
155 875
130
o
185 961
135
o
218 988
140
o
254 968
145
o
288 911
150
o
320 833
155
o
351 742
160
o
375 653
165
o
395 567
170
o
410 486
175
o
420 435
180
o
423 423
Coecients of Utilization
Eective Floor Cavity Reectance 20%
rc 80% 70% 50% 30% 10% 0%
rw 70 50 30 10 70 50 30 10 50 30 10 50 30 10 50 30 10 0
RCR
0 109 109 109 109 102 102 102 102 89 89 89 76 76 76 65 65 65 59
1 99 95 91 87 93 89 85 82 77 74 72 66 64 62 56 55 54 49
2 90 83 76 71 84 77 72 67 67 63 59 58 55 52 49 47 45 41
3 82 73 65 59 77 68 61 56 59 54 50 51 47 44 44 41 38 34
4 75 64 56 50 70 60 53 47 53 47 42 46 41 37 39 36 33 29
5 69 57 49 43 64 54 46 41 47 41 37 41 36 33 35 32 29 26
6 64 51 43 37 59 48 41 35 43 36 32 37 32 29 32 28 25 22
7 59 46 38 33 55 44 36 31 39 33 28 34 29 25 29 25 22 20
8 55 42 34 29 51 40 33 28 35 29 25 31 26 23 27 23 20 18
9 51 39 31 26 48 36 29 25 32 27 22 28 24 20 25 21 18 16
10 48 35 28 23 45 34 27 22 30 24 20 26 22 18 23 19 16 15
OCCUPANCY SENSOR FACTORY SETTINGS DETAILS
100%
Occupancy Light Level - ‘High Light Level’
When ‘Occupancy’ is detected, the xture will remain or
switch on at the set dimming level or ‘High Light Level’.
Hold Time - ‘Zero Occupancy Time’
Time required with zero occupancy before dimming to
the ‘Low Light Level’ mode or switching to an ‘o state’.
Standby Dim Level - ‘Low Light Level’
After ‘Hold Time’ elapses with zero occupancy detected the
xture will dim to the ‘Low Light Level’ or standby dim level.
5 min
10%
Standby Period - ‘Time to OFF State’
Time required after ‘Hold Time’ elapses before the xture
will switch to an ‘o state’ with zero occupancy detected.
If set to 0 seconds, xture will switch to an ‘o state’ after
‘Hold Time’ elapses. If set to +∞, the xture will stay in the
‘Low Light Level’ mode until occupancy is detected.
5 min
Fast Walk Slow Walk
Mounting Height
9.8’’
(3m)
Mounting Height
19.7’
(6m)
Mounting Height
29.5’
(9m)
Additional Factory Sensor Settings
1,2
Function Factory Settings
Detection Area 100% (sensor range)
Sensitivity Level HS - High Sensitivity
Daylight Sensor Disabled
Notes:
1. Settings can be changed using the (70205101) remote programmer.
(Max handheld remote programmer operating distance of 49.2’ (15m))
2. See Instruction Manual for operation and additional setting details.
Sensor Detection Pattern & Range
Sensor Orientation