User's Manual

Table Of Contents
SFFR-6 User Manual
Configuration
Doc ID: ES1002-UM02-v508
Page 26 of 63
3.3.2 Adding an Analog Conventional Repeating Profile
3.3.2.1 Standalone Mode
To create a new Analog Conventional Profile, click the Analog Conventional menu item in the navigation pane and click on
+ Add Profile button on the content pane.
The following fields will be required to be completed.
Profile Name
Duplexer Group Tag
Rx Frequency
Rx Subaudible
Rx RSSI
Tx Frequency
Tx Subaudible
Tx Power
Tx Hang Time
The fields are described in detail below in section 3.3.4.
Once the form has been completed, press the Save button to save the profile or Cancel to abort the operation.
Once a P25 Networked profile is selected, the IP address of the GoBox Web Interface will change to the new IP
address. To re-connect to the GoBox Web Interface at http://172.16.10.1 turn the rotary dial on the control
interface until “Standby” is displayed in the Status Window.
!
Once Save is pressed and all fields contain valid values, the profile is written to the GoBox.
!