User's Manual

Table Of Contents
SFFR-6 User Manual
Configuration
Doc ID: ES1002-UM02-v508
Page 24 of 63
3.3 Managing Operational Profiles
GoBox profiles are managed under the Profiles heading in the navigation pane. The types of profiles which can be
configured depend on the installed options.
3.3.1 Adding a P25 Conventional Repeating Profile
3.3.1.1 Standalone Mode
To create a new P25 Conventional Standalone Repeat Profile, click the P25 Conventional menu item in the navigation pane
and click on + Add Profile button on the content pane.
The following fields will be required to be completed.
Profile Name
Duplexer Group Tag
Rx P25 Type
Rx Frequency
Rx NAC (if the Rx P25 Type is Normal or Selective)
Rx/Tx Talkgroup (if the Rx P25 Type is Selective)
Tx Frequency
Tx NAC (if the Rx P25 Type is Normal or Selective)
Tx Power
Tx Hang Time
The fields are described in detail below in section 3.3.4.
Once the form has been completed, press the Save button to save the profile or Cancel to abort the operation.
If the user enters an invalid value in any form field, the GoBox will reject the profile, and the reason will be
displayed on the form in red.
!
Hovering over any form field name that has a dotted underline will display a popup tip to assist completing the
form.
!