SDS
Ethanol Shield
Conforms to OSHA CFR 29 1910.1200 and aligns to the United Nations Globally Harmonized System
Conforms to The United Nations Regulation Globally Harmonized System
Page 8 of 12
Section 11- Toxicological Information
11.1
Product Name
Results
Species
Dose
Exposure
Blend of alkoxylated alcohol,
alkoxylated cresol, saturated fatty
acid, anti- corrosive and modified
glycol ether
Oral
LD50
Rat
554.9 mg/kg
None Listed
Blend of alkoxylated alcohol,
alkoxylated cresol, saturated fatty
acid, anti- corrosive and modified
glycol ether
Inhalation
LC50
Rat
*3.358mg/l
None Listed
Blend of alkoxylated alcohol,
alkoxylated cresol, saturated fatty
acid, anti- corrosive and modified
glycol ether
Dermal
LC50
Rabbit
524.9 mg/kg
None Listed
*Inhulatiom mist
11.1.1 OECD Guideline Test results found in the European Chemical Agency Data Base shows that components
of this product to cause Oral Toxicity.
11.11.2 OECD Guideline Test results found in the European Chemical Agency Data Base shows that mist of
components of this product to cause Inhalation Toxicity.
11.11.3 OECD Guideline Test results found in the European Chemical Agency Data Base shows that components
of this product to cause Dermal Toxicity.
11.2 Route of Entry: Inhalation, Ingestion, Absorption, Skin and/or Eye Contact
11.3 Aspiration Hazard: European Chemical Agency Data Base shows that components of this product may be
fatal if swallowed and enters airways.
11.4 Mutagenicity: OECD Guideline Test results found in the European Chemical Agency Data Base show
components of this product to cause genetic defects.
11.5 Skin Corrosion/Irritation: OECD Guideline Test results found in the European Chemical Agency Data
Base shows that components of this product to cause skin irritation. Repeated exposure may cause skin dryness
or cracking.
11.6 Serious Eye Damage/Irritation: OECD Guideline Test results found in the European Chemical Agency
Data Base shows that components of this product to cause serious eye irritation.
11.7 Reproductive toxicity: OECD Guideline Test results found in the European Chemical Agency Data Base
show no components of this product to cause damage to fertility or the unborn child.
11.8 Skin Sensitisation OECD Guideline Tests results found in the European Chemical Agency Data Base
show no components of this product to cause skin sensitively.
11.9 Respiratory Sensitisation OECD Guideline Tests results found in the European Chemical Agency Data
Base show no components of this product to cause respiratory sensitively.