EXTERNAL GAS HOT WATER UNIT INSTALLATION AND OPERATING INSTRUCTIONS MODELS G26 Pure 6 FOR ADVICE, REPAIRS AND FAST SERVICE 1300 367 565 20637894 (K)
INDEX INSTALLATION INSTRUCTIONS PAGE NO.
INTRODUCTION ETERNITY G26 Pure 6 INSTALLATION INSTRUCTIONS INTRODUCTION The ETERNITY G26 Pure 6 is an external electronic gas hot water heater. The ETERNITY G26 Pure 6 is supplied set at a constant 60℃ outlet temperature depending on the model purchased. Three optional remote controls can be provided for complete hot water temperature selection and if this option is used an approved temperature limiting device must be installed. THIS HOT WATER UNIT IS NOT FOR POOL OR SPA HEATING GENERAL 1.0.
DIMENSIONS CONNECTIONS 350 165 15 122 569 25 585 8 50 575 35 623 13 50 12 84 308 COLD WATER INLET R3/4 /20 WATER INLET FILTER CABLE ENTRY POINT GAS SUPPLY INLET HOT WATER OUTLET R3/4 /20 R3/4 /20 PRESSURE RELIEF VALVE 330 2
EXPLODED DIAGRAM 1 8 4 3 9 NOS.
TECHNICAL DATA 1.1 TECHNICAL DATA AND DIMENSIONS ETERNITY G26 Pure 6 Nominal hourly gas consumption MJ/h by proportional electronic gas control MODEL G26 Pure 6 MJ/H 200 Test point pressure MODEL NG LP G26 Pure 6 .65 .67 Water heating capacity raised 40℃ MODEL G26 Pure 6 L/M 16.25 Max 1200kPa Working pressure Gas injectors of the following size in mm are fitted for the approved gas types Input voltage single phase 50Hz NG LPG 1.34 1.0mm 1.65 1.2mm 240V Maximum output current 0.
TECHNICAL DATA 1.4 HEATER DIMENSIONS: DEPTH WIDTH HEIGHT 165mm 350mm 575mm 1.5 WARNING LABELS Located on the side of the cabinet. PLEASE READ THESE LABELS CAREFULLY. 1.6 INSTALLATION POSITION THIS HEATER IS APPROVED FOR OUTDOOR INSTALLATION ONLY-IT IS NOT SUITABLE FOR INDOOR USE. Refer AS 5601 for clearance details for flue terminal. In addition, ensure that the appliance installation position permits easy access for maintenance and operation.
TECHNICAL DATA AS 5601 CLEARANCE REQUIREMENTS. Openable window a T h j n f c I j h j k Ref.
GAS CONNECTION 1.8 GAS CONNECTION (1) Fit a union to the water heater gas inlet for easy connection and removal. The thread diameter is R3/4 /20 THIS DOES NOT INDICATE THE SIZE OF THE GAS SUPPLY refer to AS 5601 for guidance on pipe sizing. (2) Fit an AGA approved isolating gas cock in the supply line adjacent to the water heater gas connection.
COLD WATER CONNECTION 1.9 COLD WATER SUPPLY TO WATER HEATER Refer to the Technical Sheet for the position of connections. Minimum of R3/4 /20 copper tube should be connected to the appliance. The WATER INLET connection is R3/4 /20 BSP and requires a union to allow for removal of the water heater. Pipe sizing from the cold water supply should be sized according to local BY LAWS for water supply.
HOT WATER CONNECTION 2.0 Refer to Technical sheet for position of connection. The outlet connection is R3/4 /20 male thread and requires an isolating union to allow for removal of the unit. 2.1 Install the hot water supply line to the unit in a minimum of R3/4 /20 copper tube. For units set at 50℃ this must be a minimum of Four(4) Metres to the first outlet. Refer to the instructions supplied with these models for full details. 2.
WIRING DIAGRAM AND REMOTE CONTROLS INSTALLATION SCHEMATIC OFF ON 1 2 3 4 5 6 7 8 DIP SWITCH R 1 2 MIN. MIN MAX GAS PROPORTIONAL VALVE BK P O MIN. W WATER VOLUME PROPORTIONAL VALVE GC-140 1 W W TEMPERATURE SENSOR (HEAT EXCHANGER TEMP.) TEMPERATURE SENSOR (INCOMING TEMP.) W W TEMPERATURE SENSOR (OUTGOING TEMP.
REMOTE CONTROLS Refer to Technical Sheets 4.0 The ETERNITY G26 Pure 6 comes complete, with one, two or three remote control panels, as optional extras. ONE REMOTE CONTROLS SYSTEM MODEL CMR-2251 MAIN CONTROLS TWO OR THREE REMOTE MODEL CMR-2251 MAIN CONTROLS CONTROLS SYSTEM MODEL YST-2251 SHOWER CONTROLS MODEL YST-2251S ENSUITE CONTROLS 4.
REMOTE CONTROLS CMR-2251 (Main remote Controller) This remote controller is intended to be used in the kitchen, laundry room or utility area. Digital Monitor Indicates the selected water temperature. Error messages flash in the event of a failure. ON Indicator Indicates power is on to the system. Flame Logo Indicator Indicates that a hot water faucet is open and that control of the temperature is taken at another controller. ON/OFF Button Power switch to operate this control.
MOUNTING ROMOTE CONTROLS MOUNTING AND WIRING OF REMOTE CONTROLS 4.7 REMOTE CONTROLS OPEN THE CARTON BOX AND MAKE SURE TO CHECK FOLLOWING PARTS PROVIDED.
MOUNTING REMOTE CONTROLS 1) Safety precautions on Main remote controller installation. • Connect remote controller cable after heater is unplugged. • Never install Main remote controller above a combustion appliance like hot plate or a kitchen range. • The heat will cause electrical component problems, or deform the exterior. • Install Main remote controller out of the reach of steam, water drop, spray of water from tea kettle, or electrical pot. • Do not put Main remote controller in direct sunshine.
MOUNTING REMOTE CONTROLS 1) Safety precautions on Bath remote controller / Ensuite installation. • Before remote controller installation, check the hole position considering wall stud location. • Note : Do not dismantle the remote controller due to water-proof design. • Do not install remote controller where water will contact the remote controller directly. • The remote controller cables carry low voltage, 12VDC digital. 2) Installation of Bath remote controller / Ensuite.
USER INSTRUCTIONS Operation of Main / Bath remote controller / Ensuite. Please read these instructions carefully before using this appliance. 1. Turn on the ON/OFF button. (refer to page 12.) 2. The temperature display will illuminate at 42℃. 3. The priority indicator will illuminate. 4. Select hot water temperature by pushing UP/DOWN button ( or ) on the controller. 5. Turn on the hot water faucet. Flame logo indicator will illuminate after a short delay.
HINTS FOR USING REMOTE CONTROLS FOR SAFETY AND ENERGY SAVINGS 1. Set the MAIN CONTROL to 42℃ for normal household use and to prevent small children from scalding. 2. For the dishwasher set the MAIN CONTROL to 60℃ or the temperature in the manufacturer's instructions. 3. For showering use settings between 37℃-39℃ and no cold water will be needed to be mixed, and if other hot or cold water taps are used the temperature will be maintained.
CARE OF THE ETERNITY HOT WATER UNIT 1. DO NOT HANG WASHING OR OTHER MATERIALS ADJACENT TO THE UNIT. 2. DO NOT STORE INFLAMMABLE MATERIALS WITHIN 2 METERS OF THE UNIT. 3. DO NOT TOUCH THE FLUE OUTLET OF THE UNIT DURING OR IMMEDIATELY AFTER OPERATION. 4. IF ANY GAS SMELL COMES FROM THE UNIT, DO NOT USE NAKED FLAMES TO TEST FOR GAS LEAKS. 5. TURN OFF THE GAS SUPPLY AND POWER AND CONTACT YOUR GAS SUPPLY COMPANY. CLOSE 6.
HINTS FOR USING THE ETERNITY UNIT POINTS NEEDED FOR YOUR SPECIAL ATTENTION Danger NO INSTALLATION INDOORS (May cause oxygen deficiency accident or incomplete combustion.) The unit is outdoor installation type. Never install indoor or in the bathroom. It will be extremely dangerous since it will cause oxygen deficiency and incomplete combustion. Prohibited Warning WATCH FOR GAS LEAK (May cause fire.
Warning NO DISASSEMBLY, REPAIR OR MODIFICATION CAUTION FOR INFLAMMABLE ITEMS (May cause fire, electric shock or other accidents.) (May cause fire or explosion.) No Disassemble Warning Do not disassemble or modify the units. Never fail to ask professional assistance from the dealer you have bought your unit from for such a case as installation, removing, auxiliary installation work or connection to the solar units.
Warning CAUTION TO PREVENT SCALDING Caution Check the water temperature by hand first before using shower. MEASURE TO BE TAKEN IN CASE OF EMERGENCY When there is an emergency such as earthquake or fire, apply following procedure. 1. Close the hot water outlet. Close 2. Close the gas valve and the main water valve. Close Close 3. Turn off the main power. However, in case of gas leakage, first close the gas valve then wait for the leaked gas to disperse then turn off the main power supply.
Caution DANGER OF WET HANDS INSERT POWER PLUG PROPERLY INTO TERMINAL (May cause electric shock.) Warning Check Do not touch power plug with wet hands. It is dangerous, because it can cause electric shock. Check the power plug for dust accumulation, then properly insert to the power point. DO NOT PULL POWER CORD DO NOT USE POWER CORD BUNDLED (May generate heat and cause fire.) (May generate heat and cause fire.) Prohibited Prohibited Do not turn off the power plug by pulling the cord.
Caution CONFIRM IGNITION, COMBUSTION AND EXTINCTION Check Please always check ignition, combustion and extinction of the unit by the operation lamp of the main or shower / sub remote controls. DO NOT PUT WATER ON THE REMOTE CONTROLS DO NOT INSTALL NEAR ELECTRIC APPLIANCES (May cause failure.) Check Check Do not put water on the remote controls. It will cause failure.
FAULT MONITOR FAULT MONITOR THE ETERNITY HOT WATER UNIT HAS A SELF DIAGNOSING FUNCTION FOR FAULTS. When the unit does not operate correctly an error code is displayed on the MAIN and SHOWER remote controls TEMPERATURE DISPLAY INDICATOR. The cause of the fault can be determined after checking the fault numbers display on the remote control display. Error Number of Code Flashes Problem Remedy - - Nothing operates. 000 - Power recovery detection.
WARRANTY CONDITIONS Eternity Continuous Flow 1. All Eternity water heaters must be installed by a Licensed installer. 2. Only Authorised personnel must Install, Commission or Service Eternity water heaters. 3. All Eternity water heaters must be installed in accordance with Manufacturer's Installation Instructions and in Accordance with local regulations, municipal building codes and current AS/NZS3000, AS/NZS3500, AS 3498 and AS5601. 4.
Warranty Terms Eternity Water Heaters are covered by Eternity for any cost of labour and parts in the event of a component failure due to any defects that may arise either from workmanship and or faulty material.