Unit installation
Table Of Contents

1.1 TECHNICAL DATA AND DIMENSIONS ETERNITY 16 / 20 / 26
Nominal hourly gas consumption MJ/h
MODEL 16 20 26
by proportional electronic gas control
MJ/h
125 160 200
Test point pressure
MODEL NG LP
Water heating capacity raised 40°C
MODEL 16 20 26
ML/M 10 12.5 16.25
Working pressure
Max 1200kPa
Gas injectors of the following size in mm
MODEL NG LPG MODEL NG LPG
are fitted for the approved gas types
16/20 1.35 1.35 mm 26
1.34 1.0mm
1.65 1.65 mm
1.65 1.2 mm
Input voltage single phase 50Hz
240V
Maximum output current
MODEL 16 20 26
Amp
0.37 0.45 0.47
SAIG Approval certificate no.
MODEL 16/20 GSCS 20021
26 GSCS 20021
Inlet gas connection male thread
18mm
Cold water connection male thread
MODEL 16/20 13mm
26 18mm
Hot water connection male thread
MODEL 16/20 13mm
26 18mm
Relief valve pressure setting
14001cPa
Weight dry
MODEL 16/20 16kg
26 17kg
1.2 DATA PLATE
Left outside of cabinet
1.3 GAS TYPE
The temporary gas label is located on the cabinet top.
The label is the gas that this appliance is designed to operate with.
16
20
26
.40
.40
.56
.61
.68
.70
DO NOT OPERATE WITH ANY OTHER GAS TYPE.
TECHNICAL DATA
4