Specifications

14,
L 1011
OKIVCX.LOC
FAN COVER
Fan
Heat sink
LED PCB
HEAD COVER
Fan support-
2.2 SETTING UP (MASTER/SLAVE)
When units are connected in seriesusing DMX512 signalcable connect the units
as shown inthe diagram below
Connect the (male)3 pin connectorside of the DMX cable to the output (female)3
pin connector ofthe first (MASTER) fixture.
Connect the endof the cable coming from the MASTER fixture whichwill have a
(female)3 pin connector to the input connector ofthe next fixture consisting of a
(male) 3 pin connector.
*Then proceed toconnect from the output as statedabove to the input of the
following fixture andso on.
*Set the firstunit in theseries to on e of the STAND ALONE modes as de scribedin
section 2.2
All other unitsin the series should be setto <SLAVE> from the <operation> menu.,
2.3 SETTING UP (DMX512 CONTROLLER)
When units are connected
in series to
a DMX512 controller
and
other
DMX512 equipment, connect the equipment as shown in the diagram
below.
*Connect the (male)3 pin connectorside of the DMX cable tothe output
(female) 3 pinconnector of the controller.
Connect the end of the cable coming from the controller which will
have a (female)3 pin co nnectorto the input connector of the next fixture
consisting of a(male) 3 pm connector.
Then proceed to connect from the output as stated above to the input of
the following fixture an d so on.
lf over 32pcsfixtures connected ,the amplifier is needed.
2 INSTALLATION
2.4
LED PCB REPLACEMENT
Take off the head cover.
Remove the fan cover, fan, fan supports, heat sink step bystep
.
Replace the new
LED PCB.
Install all parts on the original position.
2.5
GOBO REPLACEMENT
Unlock the gobocover
;
Take out thetarget rotating gobo.
Install the newrotating gobo, lock thegobo slot door.
0130 SLOT DOOR
2 INSTALLATION
0