ETC S4 Fresnel Specs

ETC
®
Fresnel Series
4 of 6
LAMPS
To determine Candela (Cd) or Lumens (Lm) for any other HPL lamp, multiply the Candela or Lumen value by the appropriate multiplying factor
(CdMF or LmMF) shown for that lamp in the table below.
ETC
Part #
Lamp Code Watts Volts
Initial
Lumens
Color
Temp. K
Avg.
Rated Life
Spot
Cd MF
Spot
Lm MF
Flood
Cd MF
Flood
Lm MF
RT116 HPL 750/115** 750 115 21,900 3,250 300 1.00 1.00 1.00 1.00
RT196
HPL 750/115X
750 115 16,400 3,050 1,500 .64 .74 .64 .74
RT113 HPL 575/115** 575 115 16,520 3,250 300 .77 .87 .84 .77
RT114 HPL 575/115X 575 115 12,360 3,050 2,000 .56 .56 .56 .56
RT142 HPL 375/115 375 115 10,540 3,250 300 .65 .56 .71 .49
RT143 HPL 375/115X 375 115 8,500 3,050 1,000 .45 .42 .49 .37
N/A
HPL 750/120
750 120 21,900 3,250 300 1.00 1.00 1.00 1.00
N/A
HPL 750/120X
750 120 16,400 3,050 1,500 .64 .74 .64 .74
RT115 HPL 575/120 575 120 16,520 3,250 300 .77 .87 .84 .77
RT171 HPL 575/120X 575 120 12,360 3,050 2,000 .56 .56 .56 .56
RT112
HPL 550/77*
550 77 16,170 3,250 300 .79 .85 .86 .75
RT117 HPL 550/77X* 550 77 12,160 3,050 2,000 .59 .56 .59 .56
RT160 HPL 750/230** 750 230 19,750 3,200 300 .82 .96 .86 .84
N/A HPL 750/230X 750 230 15,600 3,050 1,500 .51 .76 .53 .66
RT129 HPL 575/230** 575 230 14,900 3,200 400 .69 .67 .63 .59
RT138 HPL 575/230X 575 230 11,780 3,050 1,500 .49 .58 .52 .50
RT154 HPL 375/230X 375 230 7,800 3,050 1,000 .38 .35 .35 .31
N/A HPL 750/240 750 240 19,750 3,200 300 .82 .96 .86 .84
N/A HPL 750/240X 750 240 15,600 3,050 1,500 .51 .76 .53 .66
RT130 HPL 575/240 575 240 14,900 3,200 400 .66 .67 .60 .59
RT139 HPL 575/240X 575 240 11,780 3,050 1,500 .46 .58 .48 .50
RT155 HPL 375/240X 375 240 7,800 3,050 1,000 .38 .35 .35 .31
Source Four Fresnels rated for 750W maximum.
*77 Volt HPL lamps are for use with ETC Dimmer Doubling
technlology only.
**Photometric data was prepared using a production fixture and the Prometric CCD measurement system. Fixture adjusted for cosine distribution and tested with calibrated
lamp at rated voltage. All data normalized to nominal lamp lumens in accordance with IES LM-73-04. Testing performed at ETC West, Hollywood, CA. All other multiplying
factors extrapolated from primary test data.
For links to photometry file downloads (IES LM-63-02 format) go to www.etcconnect.com.
HPL Specified Tolerances: Watts +/- 5%, Lumens +/-7%, Average life +/-10%, Color Temperature +/- 50K