Setup Guide Instruction Manual

ETC Setup Guide
SmartPack™ Portable
SmartPack Portable Setup Guide Page 6 of 6 Electronic Theatre Controls, Inc.
DMX
DMX may be daisy-chained from one panel to another utilizing the XLR connectors on the front of the
unit. When daisy-chaining DMX, utilizing only the XLR connectors, the DMX-Thru connector is self
terminated when no connection is made.
System Test
After power is applied to the unit and all loads are properly connected to the output panel, select the
operating language and test each load using the Test Menu.
Select the Operating Language
Step 1: Apply power to the unit. Available languages for SmartPack will scroll in the display at 3-
second intervals.
Step 2: Press when the preferred language is displayed:
Set Language - English
Choisir la langue - Français
Sprache auswählen - Duetsch
Seleccionar isioma - Español
Set a Level for a Dimmer
Step 1: Press to enter the Test menu.
Step 2: Use < or to scroll the list of dimmers, selecting one or [ALL]
Step 3: Use + or - to set a level, press .
Step 4: Press . “Exit Test Mode” displays.
Exit Test Mode and retain all Test levels, scroll to [Keep Test On] and press .
Exit Test Mode clearing all Test levels and return to the previous menu, scroll to
[Test: all off], press .
Press < to return to the Test Menu
Press << to exit the Test Menu, clearing all Test levels, and return to the main menu.