Setup Guide Instruction Manual

ETC Setup Guide
SmartPack™ Portable
SmartPack Portable Setup Guide Page 2 of 6 Electronic Theatre Controls, Inc.
Electrical Requirements
CE Electrical Requirements
3 Phase Requirements (Europe)
1 Phase Requirements (Europe)
UL Electrical Requirements
Power Input
A 5 core x 6mm
2
double insulated tough rubber sheath cable (HO7) is required (not supplied).
230V / 400V AC, 50-60Hz, 3P+N+PE
Maximum and required current 32A per phase
Colour Code:
Green / Yellow = Protective Earth (PE)
Blue = Neutral
•Black = L1
•Brown = L2
Grey or Black = L3
A 3 core x 10mm
2
double insulated tough rubber sheath cable (HO7) is required (not supplied).
230V AC, 50-60Hz, 1P+N+PE
Maximum current 63A
Colour Code:
Green / Yellow = Protective Earth (PE)
Blue = Neutral
Brown = Phase
40A, 120V / 208V AC, 3 Phase, 4 wire and ground, 50 / 60Hz, 8/5 or 6/5 SO, SJO or equivalent
60A, 120V / 240V AC, 1 Phase, 3 wire and ground, 50 / 60Hz, 6/4 SO, SJO or equivalent
Color Code:
Green = Ground / Earth
White = Neutral
•Black = L1
Red = L2
Blue = L3
Three Phase Configuration
Earth NL1L2L3
To Circuit Breakers
(factory wiring)
Earth NL1L2L3
Single Phase Configuration (Europe)
To Circuit Breakers
(factory wiring)
Important Note
Jumper wires must match specifications for
incoming line wire.
Earth NL1L2L3
Single Phase Configuration (US)
To Circuit Breakers
2C 1C
2B 1B
2A 1A