User Manual

14 CEM3 Sensor Portable Pack Retrofit Manual
Replace AF Cards (AF Packs Only)
If your pack supports Advanced Features (AF) you will need to replace the AF card as well.
If you identified your pack as AF when ordering, a new AF card should have been sent with
your upgrade kit. If you do not have the new AF card, you may continue with the retrofit and
you can add AF cards at a later date without having to disassemble the pack. While the
pack is opened, however, it is a good time to easily swap out the cards.
AF cards are located on the right side of the dimmer module slot between the copper
neutral busses and the dimming circuitry cards.
To replace the AF cards:
Step 1: Remove the old AF card by flipping the white
retainer tab on the card into the down position.
Step 2: Pull the old card out of the slot.
Step 3: Verify that all DIP switches on the new card
are in the “off” (down) position. This
designates the card as address #1.
Step 4: Slide the new AF card completely into the
vacant slot.
Step 5: Flip the white tab up to lock the new card in
place.
Install New Pack Lid and Reassemble Pack
A new pack lid with the appropriate beacon board and Sensor3 sticker is included in the kit
Step 6: Place the new Sensor3 pack lid partially in place and in the upright position over
the output connector side of the pack.
Step 7: Connect the new DMX ribbon cable to the blue connector on the rear of the
backplane and to the DMX connector on the beacon board in the pack lid.
Step 8: Connect the CAT 5 cable to the RJ-45 port on the rear of the backplane and to
the RJ-45 connector on the beacon board in the pack lid.
Flip tab down, pull card out
1
2