Specifications

ETC Release Note:
Eos/Ion Software v1.4.0
Eos/Ion v1.4.0 Release Note Page 10 of 10 Electronic Theatre Controls, Inc.
3416 Lose LED momentarily when you switch sub types in blind
3415 Snapshot does not restore monitor configurations correctly.
3393 Cannot access a blind record target from [Blind] [Target] [Enter]
3374 Whole cue info not visible on cue with many parts
3370 Recalling snapshot of expanded direct selects leaves direct selects blank
3329 When an address conflict occurs within different parts of the same channel, a confirmation is not required.
3288 Red exclamation marks are staying on the Patch display when using Undo
3275 Selecting an address that is in a range that a fixture is already using does not assign the whole range to a channel
3107 From RFR, out not terminating command line.
3105 RFR softkeys intermittently blank upon startup
3098 Grey shading on Universe number boxes do not follow selected universe
3062 Changing effect types in blind does not update automatically
3055 SGM Idea Spot 575 has Gobo Wheel 2
Workaround: Use the CTC encoder
3039 MoveTo does not work when source and target overlap
3024 RFR submaster thumbwheel generates syntax errors.
2990 EOS always subscribes to MIDI/SMPTE Timecode with ID = 1
2937 MIDI time code events not syncing up between Master and Backup after opening from a different show
2914 EOS not responding to Stop all or Resume all MIDI instructions
2855 Fader wings cannot be stacked when using USB 2.0
Workaround: Place USB 1.1 Hub inline with wings, or connect each wing separately.
2823 Fader combination buttons not recording to macros
2771 MOVE TO with PART CUES leaves behind whole CUE number with data
2769 CUE[X] COPY TO CUE[y] should copy CHAN level commands exactly
2764 The timing is incorrect when stealing/overriding channels from a Step Effect via a cue.
2758 Able to lock the Cycle Time of a Step Effect at a negative number using the encoder
2753 Going from the Patch display to the Blind display via [Cue] [Cue] causes a syntax error.
2752 Step based Effect, Blind Editor, cannot edit the selected steps multiple times.
2737 In table views of Live/Blind, flags (e.g. M, B) are cut off on channels 5/10/15/20/etcetera.
2636 The MSC command format 7F for All-types does not work.
2590 Applying a BLOCK to a cue where an EFFECT is tracking causes EFFECT to be replaced by LEVEL preceding EFFECT
2567 Step Based Effects - Out of range values for ON STATE and OFF STATE are allowed
2476 In Live, magenta tracking zero level minus signs remain displayed after a [Go To Cue] [Out] command.
2447 A Step Effect playing the HTP game with a Sub is not being displayed correctly in Live.
2406 Physical Slider Pot handles do not accurately track between two consoles when moving multiple pot handles.
2401 The command line is not displaying LTP when toggling a Cue List between HTP and LTP.
2348 Cannot select a range of address that spans multiple universes using the port/offset syntax.
2316 Step Effect – deleted steps reappear if an arrow key is the first key pressed after deleting.
2066 A macros that includes the [Tab] button is a macro that causes a syntax error.
2057 Copying a part cue to a whole cue creates that cue with parts 3 and 10.
2050 Faders that do not physically track are causing levels to jump.
1996 [Select Active] is not grabbing active channels within a single part.
1758 Cue faders are incorrectly taken when running a looping show.
1750 Blind Channel view, there is no indication of a partially Asserted channel.
1590 Toggling between LIVE and BLIND should not page the Channel display
1568 In Live, <Channel> [X] [At] [Enter] is leaving a MOVE to zero level when previous cue was null
1564 [Flip] is not sending fixtures to the exact same position.
1289 Cannot specify a parameter on the command line and use the Encoder.
453 Independent Submaster channels incorrectly turn grey.
Known Issues Remaining in v1.4.0 [Continued]