Owner manual

A Eos Configuration Utility 383
Relay Out (remote trigger connector)
Allows you to set the Group and Address In values for the remote trigger port on the back of Eos Ti
and Gio.
RFR
This screen is used for setting up the Radio Focus Remote (RFR) to work with Eos Ti, Eos, and Gio.
For more information on RFR, see Radio Focus Remote (RFR), page 411 For additional RFR
settings, see {RFR Settings}, page 133.
USB RFR Settings
These settings need to match between the desk and the RFR. For more information on changing
the frequency and ID at the remote, see Change Frequency and ID Setting, page 413.
High Frequency Channel
The frequency that the RFR is using. There are 1-12 channels.
Network ID
The Network ID is a separate digital channel on a single high frequency (HF) setting. There are 1-
99 IDs available.
1
2
3
4
5
6
7
8
15
14
13
12
11
10
9
Ground
Ground
+ 12Vdc
+ 12Vdc
S1
S2
S3
S4
Relay Out, Normally Closed
Relay Out, Normally Open
Relay Out, Common
8 7 6 5 4 3 2 1
15 14 13 12 11 10 9
Remote Trigger Connector Pinout