Environment
The ColorSource PAR operates in ambient temperatures of 0°C–40°C and
comes with a variable-speed fan. The ColorSource PAR is for indoor use only.
Maximum recommended ambient operating temperature: Ta=40°C
(104°F)
Maximum anticipated external surface temperature at 40°C ambient:
Tmax = 80°C (17F)
External temperatures after 5 minutes of full-brightness operation at
25°C (7F) ambient: 3C (86°F)
External Temperature (steady state achieved) at 25°C (7F): 41°C (106°F)
Electrical
Operates between 100V and 240VAC at a frequency of 50/60Hz.
Maximum power consumption is 120 W.
Up to 9 luminaires(15 A max) may be linked via power thru connector
(10 luminaires total per circuit) when used with an R20Relay Module or
Unison Echo Relay Panel. Consult breaker trip curves when used with
other equipment. Requires power from a non-dimmable source.
Inrush:
-
120 V: 35 A (first half-cycle)
-
240 V: 49 A (first half-cycle)
Typical Power Consumption
100 V 120 V 230 V
Power Current Power Current Power Current
Idle 1.22 W 0.03 A 1.21 W 0.03 A 1.14 W 0.03 A
Direct at Full 107 W 1.07 A 106 W 0.88 A 104 W 0.46 A