Tus neeg siv phau ntawv
Table Of Contents
ETC Installation Guide
ColorSource PAR v1.7/v3.0
Specifications and Reference
For current and complete compliance and specifications, see the ColorSource
PAR datasheet at
etcconnect.com.
Environment
The ColorSource PAR operates in ambient temperatures of 0°C–40°C and
comes with a variable-speed fan. The ColorSource PAR is for indoor use only.
•
Maximum recommended ambient operating temperature: Ta=40°C
(104°F)
•
Maximum anticipated external surface temperature at 40°C ambient:
Tmax = 80°C (176°F)
•
External temperatures after 5 minutes of full-brightness operation at
25°C (77°F) ambient: 30°C (86°F)
•
External Temperature (steady state achieved) at 25°C (77°F): 41°C (106°F)
Electrical
•
Operates between 100V and 240VAC at a frequency of 50/60Hz.
•
Maximum power consumption is 120 W.
•
Up to 9 luminaires(15 A max) may be linked via power thru connector
(10 luminaires total per circuit) when used with an R20Relay Module or
Unison Echo Relay Panel. Consult breaker trip curves when used with
other equipment. Requires power from a non-dimmable source.
•
Inrush:
-
120 V: 35 A (first half-cycle)
-
240 V: 49 A (first half-cycle)
Typical Power Consumption
100 V 120 V 230 V
Power Current Power Current Power Current
Idle 1.22 W 0.03 A 1.21 W 0.03 A 1.14 W 0.03 A
Direct at Full 107 W 1.07 A 106 W 0.88 A 104 W 0.46 A
ColorSource PAR Page 13 of 16 ETC