Mask
You can mask whole groups of parameters (FCB) or single parameters in a group with the MASK
key.
When mask is active it is indicated in the LED of the MASK key, and at the top of the
screens.
The mask is used when recording Presets, Palettes and Dynamics.
Masked parameters are displayed in Live tab Attributes view and in the ML LCD on the
facepanel with "--".
When you record a Preset or Palette, masked parameters are NOT recorded.
You can prepare and store 999 Mask templates and activate as the global mask anytime.
User Masks can be accessed as content in the Direct Selects.
Global Mask - Functions
Function Key Feedback
Enable/Disable Mask
[MASK]
The LED in MASK is lit.
In the Main Display you
can see "Mask: and "-" for
nothing, "fcb" for partial
and "FCB" for full
masking. On the top of
every screen you can see:
Mask FOCUS
[MASK] & [FOCUS]
Toggles the Mask for the
all FOCUS parameters
Mask COLOR
[MASK] & [COLOR]
Toggles the Mask for the
all COLOR parameters
Mask BEAM
[MASK] & [BEAM]
Toggles the Mask for the
all BEAM parameters
Mask parameter
[MASK] &
[Wheel_Key]
Toggles the Mask for any
single parameter
Open Mask editor
[MODIFY] & [MASK]
Opens the Mask editor (see
below).