User's Manual
Table Of Contents
- Introduction
 - Specifications
 - Basic Assembly
 - Installation
 - Adjustments
 - Clean the Lens
 - RDM Values
 
10 Irideon FPZ
8: Insert the oval-shaped covers into the canopy 
enclosure to cover the canopy screw 
openings.
9: Restore power at the disconnect device.
Install Canopy Fixture 
(0–10 V and DALI variants)
1: Remove the adhesive tape or fasteners 
securing the mounting plate to the 
fixture to free the mounting plate from 
the canopy enclosure.
2: Are you flush-mounting the fixture or 
surface-mounting the fixture? 
• Flush-mounting: Using the mounting 
plate screws, secure the mounting 
plate to the installed backbox.
• Surface-mounting: Position the cover 
plate on top of the mounting plate, 
and use the mounting plate screws 
to secure both plates to the 
installation surface. The cover plate is 
required when the interior of the 
canopy enclosure could be exposed 
after installation with only the 
mounting plate (the mounting 
surface is smaller than the canopy 
enclosure).
Note:
The 0–10 V driver conforms to IEC 60929 Annex E. Of the 
0–10 V range, use 0–1 V to set the minimum level, and 
use 1–10 V for continuous dimming.
Note:
The canopy fixture can be installed directly on 4” and 
4-11/16” backboxes, or on backboxes with round cover 
plates. The canopy fixture cannot be installed on 1-gang 
backboxes or trim rings.
WARNING:
RISK OF ELECTRIC SHOCK! Install the cover plate as 
directed below for installations where the interior of the 
canopy enclosure could be exposed after installation 
with only the mounting plate. For example, install the 
cover plate when installing to a surface-mount backbox. 
Oval-shaped covers
Mounting 
plate
Canopy 
screws
Mounting 
plate screws
Cover plate 
(if needed 
for surface-
mounting)
(DALI 
variant 
shown)