User Manual 7
If using Category 5:
a: See the 
Cat5 Cable Preparation for 
IDC Termination Setup Guide
 for 
instructions to prepare and 
terminate Category 5 for DMX/RDM 
input cable to the insulation 
displacement connector.
b: Install the IDC connector with wires 
terminated to the DMX/RDM Input 
receptacle on the termination board.
4: Optionally, terminate DMX/RDM thru to 
the next device in the DMX data run. 
Up to 32 DMX/RDM devices can be 
daisy-chained together per data run.
a: See the specific termination setup guide for the type of cable used 
(either Belden 9729 or Category 5) in the installation. Termination 
kits are ordered separately.
b: Install the connector with wires terminated to the DMX/RDM Thru 
receptacle on the termination board.
5: Connect the building ground wire to the power block on the fixture.
6: Following the label on the mounting plate, attach the power wires to 
the power block.
Data – (ORG)
Data + (W/ORG)
Cat5 (or equivalent) wire
termination to IDC connector
COM
BRN
GRN
W/GRN
BLU
W/BLU
 DMX
termination
board
Power block