User's Manual
Table Of Contents
- Introduction
 - Specifications
 - Basic Assembly
 - Installation
 - Adjustments
 - Clean the Lens
 - RDM Values
 
18 Irideon FPZ
Initial Power Up
Track-Mount, Portable, and Canopy (DMX) Fixtures
Control and configure the fixture over a DMX/RDM control network or directly 
from a connected computer running appropriate software. When controlling 
the fixture directly from a PC, a Gadget II interface or DMX/RDM gateway is 
required.
Canopy (0–10 V) Fixture
Apply power and dim the fixture using a 0–10 V controller.
Canopy (DALI) Fixture
Use a DALI configuration and commissioning tool to configure the DALI 
address of the fixture. 
Status LED
The status LED indicates the DMX status. When DMX is present, the LED turns 
on for 10 seconds, and then it turns off.
When the local intensity is set to Off, the status LED will flash when there is a 
loss of DMX.
With the local intensity set to any other position, the status LED will flash for 
10 seconds when there is a loss of DMX. Then the LED will turn off.
Note:
Changing the address via RDM will override the local 
DMX addressing dials. However, if you change the 
addressing dials after you set the address via RDM, the 
addressing dials will override the RDM setting. See Set the 
DMX Address on the Fixture on page 15.
Note:
The 0–10 V driver conforms to IEC 60929 Annex E. Of the 
0–10 V range, use 0–1 V to set the minimum level, and 
use 1–10 V for continuous dimming.
Note:
A change to the DMX start address, the local intensity, or 
the presence of DMX will “wake” the status LED.