POWER MANAGEMENT FUNCTION
With the power control function, you can set the total power to 2,5 kW / 3 kW / 4,5 kW /
6,5 kW a 7,4 kW. The default total power setting is the maximum power level.
Setting the maximum overall power level
We suggest to enter the power setting mode within 30 seconds from conecting to enter
Power Management Function.
1. Please be noted that do not turn on the hob. It is not necessary to place any pots on the
cooking zones.
2. Touch the pause
button and hold for 5 seconds. You can hear the buzzer beeps one time.
3. After you hear the beep, touch “+” and “-” button at the same time and hold for
3 second, the timer indicator will show flashing previous total power level, e.g. ‘2.5’.
4. Touch and hold + and - for 1 second again to switch to other power level for example
3.0. When the power that you want is flashing, touch the button pause
and hold for
5 seconds.
5. The buzzer will beep 10 times. It means you have finished the setting.
Note:
• After step 2, you must touch the + and - within 3 seconds after you hear the beep.
Otherwise you will need to start again from step 2.
• Once finish setting, wait till the end of 10 beeps. Do not touch any button during this
period. Otherwise the setting will be invalid.
Power Management Rules
If total power exceeds the limitation of 2.5kw, 3.0kw, 4.5kw or 6.5kw (depending on which
level you've set), you are not able to increase power stage of any zone. If you increase it by
touching +, the cooktop will beep 3 times and indicator will show a flashing "Pn". Thus you
need to decrease power stage of other zones before increasing the power of objective zone.