User Manual

EN - 59
EN
The power cable must not come into contact with hot surfaces and must be routed so
that the temperature does not exceed 75 °C at any point.
Consult an electrician to see if the home wiring is suitable without further modifications.
Any changes may only be made by a qualified electrician.
The socket should be connected in compliance with
the relevant standard to a adequate circuit breaker.
The method of connection is shown below.
Voltage Wire connection ETA579190000
380 - 415 V 2N ~
1 2
3 4
5
NL1 L2
black brown gray blue yellow/green
220 - 240 V ~
1 2
3 4
5
NL
black brown gray blue yellow/green
If the cable is damaged or needs to be replaced, this work must be carried out by
a contracted service technician or a certified specialist with prescribed qualifications for
this activity in accordance with current local standards and regulations, otherwise an
injury could occur.
If the appliance is being connected directly to the mains supply, an omnipolar circuit
breaker must be installed with a minimum gap of 3 mm between the contacts..
The cable must not be bent or pressed anywhere.