User Manual
EN - 56
EN
Failure display and inspection
The onduction hob is equipped with a self diagnostic funkcion. With this test the technican
is able to chceck the funkcion of several components without disassembling or dismounting
the hob from the working surface.
Failure code Problem Solution
F3/F4
Temperature sensor of the induction
coil failure
Please contact the supplier.
F9/FA
Temperature sensor of the IGBT
failure.
Please contact the supplier.
E1/E2 Abnormal supply voltage
Please inspect whether power
supply is normal.
Power on after the power
supply is normal.
E3
High temperature of the induction
coil temperature sensor
Please contact the supplier.
E5
High temperature of the IGBT
temperature sensor
Please restart after the hob
cools down.
The above are the judgment and inspection of common failures.
Please do not disassemble the unit by yourself to avoid any dangers and damages to the
induction hob.
VII. INSTALLATION
CHOOSING A LOCATION FOR INSTALLATION
ETA579190000
D (mm) 51
L (mm) 590
W (mm) 520
H (mm) 55
A (mm) 560
+5
B (mm) 490
+5
X (mm) 50 min
seal