Datasheet

www.e-t-a.de
13
3120-N...-...T1-... Thermal Circuit Breaker
1930
1
3120-N...-...T1-... Thermal Circuit Breaker
Technical data (X3120-B, without filter) Technical data (X3120-A, with filter)
Voltage ratings AC 240 V
Current rating
(appliance inlet)
16 A (IEC)
20 A (UL/CSA)
Operating temperature -25 °C … +60 °C
Number of poles L, N + mass
Degree of Protection I
Mounting method: screw-type mounting
(from the front or from the rear)
Terminal design: blade terminals DIN 46244
6.3 mm x 0.8 mm
Housing material: thermoplastics, black, UL94V-0
Appliance inlet: C20 to IEC/EN 60320-1, UL498
Main switch: circuit breaker for equipment protection
3120-N5.6
Voltage ratings AC 250 V
Current rating
(appliance inlet)
10 A (IEC)
15 A (UL/CSA)
Ratings of filter 1 A, 3 A, 6 A, 8 A, 10 A, 12 A, 15 A
Operating temperature -25 °C … +60 °C
Number of poles L, N + mass
Degree of Protection I
Mounting method: screw-type mounting
(from the front or from the rear)
Terminal design: blade terminals DIN 46244
6.3 mm x 0.8 mm
Housing material: thermoplastics, black, UL94V-0
Appliance inlet: C14 according to IEC60320-1, UL 498
Main switch: circuit breaker for equipment protection
3120-N5.6
Mounting cut-out (X3120-B)
Mounting cut-out (X3120-A)
Dimensions (X3120-B)
Dimensions (X3120-A)
5.5
0.21
Schutzschalter 3120
26
47
1.0
1.85
37
1.457
100
3.54
3.9
90
Ø 3.4
Ø .133
36.2
1.43
80
3.15
91.5
3.60
Ø 3.4
Ø .133
49.2
1.937
12.7
,0.5
40
1.57
90
3.543
79.5
3.129
32.5
0.137
Ø3.3
Ø0.129
80.0
3.15
72.0
2.834
R3.0 (4x)
.12 (4x)
Ø 3.6 (2x)
Ø .14 (2x)
29.0
1.141