Datasheet
www.e-t-a.de
4
 3120-N... Thermal Circuit Breaker
1846
 1
Approvals
Time/current characteristics
The time/current characteristic depends on the ambient temperature. In 
order to eliminate nuisance tripping, please multiply the current rating 
by a derating factor. For further details please see: www.e-t-a.de/ti_e
ambient 
temperature [°C]
-30 -20 -10 0 23 40 50 60
temperature factor 0.8 0.84 0.88 0.92 1 1.08 1.14 1.23
... times rated current
Trip time in seconds
... times rated current
Trip time in seconds
10
 23 °C 
 60 °C 
-30 °C 
12468102040
10000
1000
100
1
0.1
 23 °C 
 60 °C 
-30 °C 
12468102040
10000
1000
100
10
1
0.1
0.1…2 A
2.5…20 A
1.4
1.4
Approval 
authority
Standard Voltage 
ratings
Current rating 
range
Approval 
logos
VDE IEC/EN 
60934
AC 240 V
DC 50 V
DC 50 V
DC 28 V
0.1 A … 20 A
0.1 ... 20A (2-pole)
0.1 ... 16 A (1-pole)
0.1 A … 20 A
UL UL 1077
AC 250 V 
AC 250 V 
DC 50 V 
AC 250 V
0.1 A ... 16 A 
(TC1, OL1) 
17 A … 20 A  
(TC1, OL0) 
0.1 A … 20 A  
(TC1, OL0) 
30 A*   
(TC1, OL0)
CSA C22.2 
No 235
AC 250 V 
AC 250 V 
DC 50 V 
AC 250 V
0.1 A ... 16 A 
(TC1, OL1) 
17 A … 20 A  
(TC1, OL0) 
0.1 A … 20 A  
(TC1, OL0) 
30 A*   
(TC1, OL0)
CQC GB 
17701
AC 240 V 
DC 50 V
0.1 A…20 A 
0.1 A…20 A
KTL KC6094
AC 240 V 0.1...20 A (2-pole)
* 2 poles in parallel 