FRONT PANEL FEATURES
1. Un-switched AC Outlet–The120VACoutletisalwayslivewhentheETA-S15LpowercordispluggedintoanACmainspower
sourceandvoltageispresent.Note:TheACmainspowerswitchdoesnotaffecttheUnswitchedACOutlet.TheUnswitched
Outlet is protected by the surge protection circuitry.
2. AC Mains Breaker–The15AratedbreakerwillopenifthecombineddrawofallACoutletsexceeds15A.Note:Thebreakeris
designedtoexceeditsratingforashortperiodoftime.Ifthebreakeristripped,youmustfirstremovetheloadfromtheETA-S15L
and then push to reset.
3. Power Switch –ToturntheETA-S15Lonoroff,presstheswitchtotheONorOFFposition.
4. Pull Out Light –TheLEDlightisdesignedtobepulledoutwhenneeded.
5. Pull Out Light Dimmer Switch –UsethiscontrolforthePullOutLight.Settingsincludean“Off”positionandtwobrightnesssettings,
LowandHigh,when“On.”
6. Power ON LED Will illuminate blue when the AC Mains Power Switch is in the ON Position.
7. AC Fault Indicator Although the Clamping Suppression circuit virtually assures protection from most transient voltage spikes and
surges, nature has a way of occasionally creating electrical forces that are beyond the capabilities of any device to absorb without
somedegreeofdamage.Intherareinstancethatthisoccursandthecircuithasbeendamaged,theRed“ACFault”LEDindicator
willilluminateandaninternalbuzzerwillsound.TheETA-S15Lwillalsoshutoffpermanentlyuntiltheunitisrepaired.Beadvisedthat
activationofthisfaultconditionandtheassociatedrepairisnotcoveredunderwarranty.NOTE:IftheACFaultLEDisilluminatingitis
importanttohaveallequipmentthatwasconnectedtothatACMainsLinebeinspectedforproperoperation.
REAR PANEL FEATURES
1. AC Mains Input Connectthe9'(3m)powercordtoa15A120VACoutlettoprovidepowertotheETA-S15L.
2. AC Power Outlets Theseeightoutletsare“Live”whenthefrontpanelpowerswitchisactivated.
3. XLR Light Socket A12VDCXLRlightsocketprovidespowerfortheoptional,AtlasPower,AP-GNL18light.
4. Light Socket Power Switch ThisswitchturnstheXLRlightsocketON/OFF.
INSTALLATION
Beforeinstalling,westronglysuggestyoureadtheentiremanualtoensureyoubenefitfromallthefeaturesoftheETA-S15L.The
ETA-S15Lcanbeplacedonashelforrackmountedinastandard19"widthrack.Whenrackmounted,placementwithintherackis
flexiblehowevertheETA-S15Lshouldbewithin6'ofadedicated15AACoutlet.Whenrackmounting,useRackRailtypescrews
which are
10
32"x1".Alwaysmakesurethe15AoutletisproperlyinspectedbyacertifiedelectricianpriortoconnectingtheETA-S15L.
MakesuretoinspecttheequipmentthatistobepluggedintotheETA-S15Ltoensureitdoesnotexceed15Atotalamperagedraw.
ETA-S15L
Power Conditioner & Distribution Unit
1 2 345 6 7
1 4 32 2