Specifications

– 9 – ETAsys.com
Specifications are subject to change without notice.
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800-321-6699 • Fax: 800-996-3821
ETA-20SH
AC Power Conditioning & Suppression Module
ETA-ECS6RM SEQUENCER CONTROLLER INTERFACE WITH ETA-20SH
To get maximum use of the ETA-20SH we suggest using the ETA-ECS6RM controller. When the two are interfaced the ETA-ECS6RM
controller can not only remotely turn on the ETA-20SH but it can monitor the AC Mains Voltage and Current of the ETA-20SH. When
paired, the microprocessor in the ETA-ECS6RM can determine if there are any potentially damaging AC Voltages present at the
ETA-20SH and shut it off before damage can occur to sensitive equipment connected.
1. ECMControlPorts – Up to 6 AC Main circuits can be activated or monitored by the ETA-ECS6RM. Each ECM control port
connects to one of the following ECM modules: ETA-ECM20, ETA-ECM20M, ETA-15SH, or ETA-20SH. For connection between
the ETA-ECS6RM and an ECM module, use a 5 conductor cable that is a minimum of 22-gauge wire. We suggest using CAT5
cable due to the common availability. Pay special attention to the port connections and DO NOT MISS WIRE or damage may
occur.ThedistancebetweentheETA-ECS6RMandanECMmodulecanbeupto1000'.
(+)=5VDC,G=CircuitGround,V=ACVoltageStatusSignal,A=ACCurrentStatusSignal,D=FaultStatusSignal,allsignals
are of low voltage and current.
2. RelayContacts – Each Channel of the ETA-ECS6RM also has a Relay contact that works in conjunction with the ECM control
port. Sequencing and timing of these connections are the same as the corresponding ECM channels. Example: Sequence
1 ECM Port output works at the same time as CH 1 Relay contact. Note: All ECM modules can be trigger using the Relay
contacts to activate the ECM module.
Single ETA-ECM20 Control Port
Relay Contacts