Specifications
– 15 – ETAsys.com
Specifications are subject to change without notice.
1601 Jack McKay Blvd. • Ennis, Texas 75119 U.S.A.
Telephone: 800-321-6699 • Fax: 800-996-3821
ETA-20SH
AC Power Conditioning & Suppression Module
ETA-20SH SPECIFICATIONS
Type AC Power Conditioning & Suppression Module
RoHS Compliant Yes
Safety Listings ETL (UL 60065 Standard)
FrontPanel
Outlet Two 20A, Switched
Indicators Active (Green), Fault (Red), Incoming AC (Red)
Manual Override Slide Switch
Connectors 5PositionPhoenixEuroBlockStyle5mmSpacing
Hard Switch Remote Trigger SPST Contact
Status Signals Output for Voltage and Current Data (All signals are low voltage and low current)
TechnicalData
Current Rating 20A
Operating Voltage 102VAC - 132VAC
Power Consumption 500 milliwatts
Power Requirements 120V 60Hz
ExtremeVoltageShutdown (EVS)Below102Vorabove132VACLine(WhenusedwithETA-ECM6RM)
DCV Remote Trigger 5-24DCV
FuseProtection 20A250V3ABSlowBlow(Internal)
PowerCord 9'(3m),12-gaugeNEMA5-20P125VACplug
High Voltage Surge Protection Trigger at 133VAC, 1ms typically (When used with ETA-ECS6RM)
Low Voltage Surge Protection Trigger at 101VAC, 1ms typically (When used with ETA-ECS6RM)
Spike and Surge Suppression Hot to Neutral, Hot to Ground, Neutral to Ground
Spike Protection Modes Circuitry on Incoming AC Mains
Min.SpikeClampingVoltage 460VRMS@3,000amps
Max. Spike Clamping Voltage 6kV
Max. Spike Clamping Resp. Time <1 nanosecond
SpikeClampingVoltage@100A 1,250Vpfor20µs
Maximum Surge Current 6,500A
Energy Rating 600 Joules
NoiseAttenuationEMI/RFISequencer 10dB@10kHz,40dB@100kHz,100dB@10MHz
Temperature Range 5° – 35°C
Humidity Range 5% to 95% R.H.
Mechanical
ChassisFinish Black
Mounting Side bracket adjustable
Height 3" H x 8.5" W x 3.5" D (76.2mm x 215.9 x 88.9mm)
Weight 5.5 lbs (2.49kg)