Product Info

1.3.5 WLAN Access Point
- No DFS, no Radar detection.
- Access point only in 2,4GHz.
1.4. PLC (Power Line Communication)
Frequency: from 1,8 MHz to 30 MHz (fixed notching)
Standard: Home Plug Green PHY
- Interface LVDS
Figure 6: Architecture LVDS COM-Board
2. Electrical safety
COM board is connected only to PWR-Board and is powered by SELV/PELV voltage 13Vdc. The COM
board has no outputs/inputs to the user. The charging cable itself has protection class IP55/enclosure
3R.
3. EMC- and Ground concept
UL2231, UL2594, FCC, Part 15 B, Class B, ICES-003, Class B
As well see Low Voltage Directive2014/35/EU, EMC Directive2014/30/EU, Radio Directive
2014/53/EU, EN 50561-1., ISO 15118,