Specifications

VMware, Inc. 315
Chapter 19 Managing Tasks, Events, and Alarms
Sendanotificationtrap
TheVirtualCenterServeristhedefaultSNMPnotificationreceiver.AnSNMPtrap
viewerisrequiredtoviewasenttrap.TheVirtualCenterServerhostmustbe
configuredtoreceiveSNMPtraps.See“PreparingforSNMPAlarmNotification”
onpage 316.
Runascript
Theuserscriptcommandanditsargumentsmustbeformattedintoonestring.
TheuserscriptisrunningasseparateprocessanddoesnotblocktheVirtualCenter
Serverprocesses.Butthescriptdoesrunandconsumetheresourcesonthe
VirtualCenterServermachine,suchasprocessorandmemory.
Suspendthevirtualmachine
Poweroffthevirtualmachine
Resetthevirtualmachine
Theactionsavailablewithalarmsaredescribedinthefollowingsections:
“PreparingforEmailMessageSMTPAlarmNotification”onpage 315
“PreparingforSNMPAlarmNotification”onpage 316
“CreatingAlarms”onpage 317
“EditingAlarms”onpage 322
“RemovingAlarms”onpage 323
Preparing for Email Message SMTP Alarm Notification
IfyouwanttouseemailmessagestosendSMTPnotifications,youmust:
DefinetheSMTPandemailmessageaddressinginformation.
Specifytheemailmessageaddressforthoseintendedtoreceivethenotification
whenyoucreate thealarm.
To define the SMTP and email message addressing information
1FromtheVIClient,chooseAdministration>VirtualCenterManagementServer
Configuration.
2ClickMailinthenavigationlist.