User`s manual
APPENDIX D
SOFTWARE COMMANDS
APX D-9
TERMCont (on/off)
The RS-232 receive termination timer.
ON: If there are characters in the RS-232 buffer and the modem is
in Converse Mode, the termination timer starts from the time
the last receive character is updated in the buffer. If the
termination time expires before another character is received,
the characters are transmitted.
Factory default = OFF.
TERMTime (1-255)
The RS-232 receive termination timer value. This value can be 1 to
255 tick intervals (1 tic = 16.67 ms.). This value time out is enabled
by TERMCONT.
Factory default = 1O.
TRans (0-255)
The transparent mode command. The execution of this command
causes an immediate exit by the ESTeem unit COMMAND mode to
TRANSPARENT mode and cannot be saved by the SAVE
command. This mode allows the ESTeem link to be completely
transparent to the communicating RS-232 devices. When in
transparent mode, and prompts are enabled, a ">" is displayed on
the terminal. If a variable is specified with this command the
ESTeem will return to the COMMAND Mode after the number of
transmissions equal the number specified.
EXAMPLE: CMD: TRANS <cr>
The ESTeem would immediately be placed in the TRANSPARENT
Mode (> prompt would be displayed) and remain in that mode until
the ESTeem was hardware reset.
EXAMPLE: CMD: TRANS 5 <cr>
The ESTeem would immediately be placed in the TRANSPARENT
Mode and would return to the COMMAND Mode after five
transmissions.
TXDATA (1-255)
This command defines the transmit data delay in milliseconds.
TXEnd (1-255)
This command defines the transmit end delay in milliseconds.
TXFlag (1-255)
This command defines the transmit flag delay in milliseconds.
TXSTAT (clear/high/low)
This command prints the total number of rf transmissions vs. the
total number of retries.
CLEAR: Initiation of this command causes the total transmit and
retry count to be zeroed.
HIGH: Initiation of this command displays the upper 16 bit value
of the total transmit count and the total retry count.
LOW: Initiation of this command displays the lower 16 bit value
of the total transmit count and the total retry count.
TYPerr (on/off)
This command enables the Communication Error Messages.
Factory default = OFF.
TYPSyste (on/off)
This command enables the System and Error Message
Commands. Factory default = ON.
VERSION
This command will display the current software version being used
by the ESTeem.
WESTCTRL (on/off)
This function enables the Westinghouse controller protocol. For
further detail Reference the EST Engineering Report on
Westinghouse controller interfacing. Factory default = OFF.
XHflow (on/off)
This command enables hardware flow control.
Factory default = OFF.
XSflow (on/off)
This command enables software flow control.
Factory default = ON.