User`s manual
APPENDIX D
SOFTWARE COMMANDS
APX D-7
RECONNEC ( on/off)
The RECONNEC command when enabled will automatically repeat
the connect attempt when "DESTINATION CONNECTED TO
ANOTHER NODE" (SS03) is displayed. The number of attempts is
determined by the RECONRET command. The time between
attempts is determined by the RECONTim command. If the modem
is unable to connect after the retry number is met, the unit will return
to the COMMAND MODE.
NOTE: The modem will not be able to receive a connect from an
outside node during the reconnect process, but the
NODE command will reveal the addresses of any
attempts to contact you.
Factory default = OFF.
RECONRet (1-255)
The RECONRET command is used with the RECONNEC
command to determine the number retry attempts before the
Reconnect is aborted. Factory default = 10.
RECONTim (1-255)
The RECONTIM command is used with the RECONNEC command
to set the time in seconds between the RECONNEC
attempts. Factory default = 1.
REMPROG (on/off)
This command will enabled will disable your ESTeem from being
remotely programmed from another ESTeem.
Factory default = 0.
REPECONF (1-255,1-255,1-255)
This command extends the usual point to point routing protocol in a
PLC to include routing data through a series of ESTeem repeaters.
This command is explained in detail in the PLC Engineering
Reports. See REPELIST command.
REPELIST
This command is used to display REPECONF Table. This
command is used in PLC interfacing. Its actual use is defined in the
specific PLC engineering reports.
RESet
The software reset command for the ESTeem. The execution of this
command resets the internal electronics in the ESTeem.
RESTore (1-2)
The restore command. The execution of this command restores the
ESTeem command variables and switches from one of two different
configurations stored in nonvolatile memory. Factory default value is
REST (1).
RETry (1-255)
The retry command number. This is the number specifying the
number of retries, retransmission of frames, that are not
acknowledged. Frames are retransmitted RETRY times before
operation is aborted. Factory default = 6.
RING (latch/pulse)
This command is used to program the ring output line on pin 22 of
the RS-232C connector.
RING LATCH: Pin 22 is high (space) when unit is connected.
RING PULSE: Pin 22 is pulsed (positive 25O ms.) when unit is
connected.
Factory default = LATCH.
RS Baud (110,150,75,50)
This command allows the user to extend the ESTeem RS-232C 110
baud rate switch setting to the following non-standard values of 150,
75, and 50 baud. The RS-232C SETUP SWITCH on the ESTeem
must be set to the 110 baud switch setting for these settings to be
enabled. Factory default is 110.
RS-stop (2.0,1.5,1.0)
This command allows software selection of the number of stop bits
in the data stream to be interpreted by the ESTeem modem via the
RS-232C. Factory default = 1.0.
RTs-cts (on/off)
This command enables the standard RS-232C handshake protocol.
ON: When enabled, this switch will allow the ESTeem modem to
respond to the RTS (Request to Send pin 4) and reply with the
CTS (Clear to Send pin 5) commands according to the
standard RS-232C specifications,
OFF: The ESTeem modem activates the RTS (pin 4) and CTS
(pin 5) according to XHFLOW (Hardware flow control
specifications). XHFLOW must be enabled. An error
message will be generated if an attempt is made to enable
RTS and XHFLOW simultaneously.
Factory default = OFF.
RXS (on/off)
This command when enabled will display the approximate received
RF signal strength of an emitter. Listed below is the output reading
an approximate microvolt (uV) conversation.
OUTPUT uV Level:
0 to 2 <10
3 to 9 >10 but <20 uV
10 to 19 >20 but <35 uV
20 to 34 >35 but <50 uV