User`s manual
CHAPTER 4
ESTEEM APPLICATION PROGRAMS
4-5
•
xxx and yyy represent an ESTeem address which is
user definable from 0 to 253.
INTERACTIVE TERMINAL APPLICATION
This program is used to connect a mainframe to a remote
terminal. This setup is a typical point to point
configuration with the AUTO-CONNECT feature
enabled.
Perform the following prior to programming the
ESTeem(s) to initialize the unit to factory default
settings:
1. Turn Bit 8 OFF on the RS-232C Setup Switch.
2. Reset the ESTeem.
3. TYPE FA <cr>. Please note the characters my not
be echoed by the crt.
ESTeem At Mainframe ESTeem At Terminal
-------------------------- ------------------------
ADD xxx ADD yyy
SETC yyy SETC xxx
TERMC ON TERMC ON
TERMT 1 TERMT 10
XSF OFF XSF OFF
XHF ON * XHF ON *
DISACK ON * DISACK ON *
SETMODE ON SETMODE ON
SETTRANS ON:SAVE SETTRANS ON:SAVE
BIT 8 ON (RS-232 SWITCH) BIT 8 ON
RESET ESTEEM RESET ESTEEM
•
Turn DISACK ON only if you want to defeat the
acknowledge packet.
•
Only hardware flow control can be used in this
mode.
•
xxx and yyy represent an ESTeem address which is
user definable from 0 to 253.
PHONE MODEM INTERFACING
This application program is for interfacing the ESTeem
to a Black Box 1200+ phone modem which is bell 212
compatible. The configuration is used to have a remote
terminal access to a phone line.
Perform the following prior to programming the
ESTeem(s) to initialize the unit to factory default
settings:
1. Turn Bit 8 OFF on the RS-232C Setup Switch.
2. Reset the ESTeem.
3. TYPE FA <cr>. Please note the characters my not
be echoed by the crt.
ESTeem At Phone Modem ESTeem At Terminal
--------------------------------- --------------------------
ADD xxx ADD yyy
SETC yyy SETC xxx
TERMC ON AUTO OFF
TERMT 50 PROMPT OFF
SENDP 255 SAVE
SETTRANS ON:SAVE
BIT 8 ON *(RS-232 SWITCH) BIT 8 ON *
RESET ESTEEM RESET ESTEEM
•
Enable Bit 8 ON only if you want the
AUTO-CONNECT feature.
•
xxx and yyy represent an ESTeem address which is
user definable from 0 to 253.
A NULL connector must be connected between the phone
modem and the ESTeem because both devices are DCE
equipment. Use normal procedures to CONNECT to the
ESTeem interfaced to the phone modem. After a
CONNECTED TO MESSAGE appears, the normal dial
up commands can be used.
Listed below is a second application program for
interfacing an ESTeem to a Hayes phone modem.
Perform the following prior to programming the
ESTeem(s) to initialize the unit to factory default
settings:
1. Turn Bit 8 OFF on the RS-232C Setup Switch.
2. Reset the ESTeem.