Instructions / Assembly

E-S 1000D Series Instruction Manual
Troubleshooting
5.15
Fix for not showing AU:
Disconnect the power to the system, wait 20 seconds, then reapply power.
The gate lock terminals are not putting out power
Causes for the issue:
The third dip switch is off (down).
The closed limit switch was not reached. The lock will only trigger when the gate is being
opened from the closed limit switch, not from stopping on run time.
Fixes for lock output not putting out power:
Disconnect power to the system, wait 20 seconds, move the 3rd dip switch to the up (on)
position and reapply power.
Increase the P1 setting by 10. it is best to do this while you have the end of the gate opera-
tor arm disconnected from the gate and you are holding it in your hand. This will allow the
piston to extend to the limit switch. Move the piston extended to its limit back to the gate
bracket and see if this lines up with your desired closed position. If it does not adjust your lim-
it switch until it does.
Gate will move too far open or closed, stops and reverses 3 feet:
There could be multiple issues at hand so please do the fixes in order. After a fix is done do not
undo that fix when moving to the next if the next is needed.
Fix sequence for gate moves too far open, stops and reverses 3 feet:
Change the P3 setting to 28. Remove the end of the piston(s) from the gate, hold it in your
hand to prevent it from spinning and run an opening cycle. If the issue still occurs, run it
again and watch the display:
If the display is showing OP and the gate is opening then the limit wires are backward.
Swap the first and third limit switch wire in the limit1 block for the primary operator or sin-
gle gate. Swap the first and third wire in the limit2 block if the issue is on the secondary
operator. If the display is showing OP but the gate is beginning to close the motor wires
are backward. Swap the position of the motor leads L1 and L2 for the appropriate motor
that is having the issue.