5.11
DUAL GATE: One leaf continues to travel past its limit switch while the other leaf stops inconsist-
ently
This is because the limit switch wires from motor 1 are in the limit 2 block and the limit switch
wires from motor 2 are in the limit 1 block. As motor 1 travels past its limit switch motor 2 will be
triggered to stop. Motor 1 will keep traveling because its limits are paired with motor 2. Howev-
er since motor 2 stopped, motor 2 will never reach its limits and motor 1 will travel until it ob-
structs.
Fix for issue of one leaf past its limit, other inconsistent:
Remove the limit 1 and limit 2 blocks and swap them
Remote will not open the gate but gate will operate from Push1 button
Possibilities of issue:
Receiver has no power
Remote has not been learned to the receiver
Remote has been learned to the wrong channel
Wiring is not correct to the receiver
Receiver plug in connection on board is not functioning
Receiver wires have an internal split
Receiver jumper is not making good contact
Fixes for the remote not working:
Look in the lower left side of the receiver at the light marked Power. If this light is not on
there is no power to the receiver. Check the wiring to the receiver (this will be described be-
low). Also check the first fuse on the left side of the board.
If you have not been through a programming sequence, this must be done prior to using
the remotes. Press and release the Learn1 button in the upper left side of the receiver - the
Learn light in the center of the board will illuminate. Press and hold a button on a remote
until that learn light on the receiver flashes and turns out.
You can now repeat this procedure for other buttons of the same remote or buttons on oth-
er remotes.