Instructions / Assembly
E-S 1000D Series Instruction Manual
Troubleshooting
5.5
If replacing the fuse does not help, the motor can be tested using the following procedure:
a. Disconnect the battery from the control board and from the charging source (solar
panel or transformer)
b. Disconnect the large Red and large Black motor wire from the control board termi-
nals L1-1 and L1-2 for primary or L2-1 and L2-2 for secondary
c. Take the red and black wires from the motor and touch them directly to the battery
terminals. This will cause the motor to run. The polarity of the red and black motor
wires on the battery positive and negative will cause the motor to extend or retract.
Swap polarity to cause the opposite reaction from the motor.
d. If the motor moves then we can assume if the board was putting out voltage from
the two terminals L1-1 and L1-2 for primary or L2-1 and L2-2 for secondary the motor
would move.
e. If the motor does not move the wire is most likely damaged, inspect the wire for
damage.
If both the above are done (fuse replaced and the motor tested direct off the battery) then
the source of the issue is one of the clear relay blocks above the L1-1 and L1-2 or L2-1 and
L2-2 terminals are no longer functioning and the board should be repaired or replaced.
Gate is open, displays shows AU and the gate will not close
AU stands for Auto Reclose. This means that the gate is in the Auto Reclose countdown. The au-
to reclose is controlled by the first dip on the red block in the center of the board. If the first dip
switch is in the up position, the gate will auto reclose after the number of seconds that have
been selected in the P6 setting have elapsed in the open position. The AU is what it displays af-
ter the gate has reached the open position and it is counting down to automatically reclose.
There are two reasons this may be on the display and the gate will not close:
If the gate opener is in the open position and power is disconnected and reconnected the
gate will not move and AU will be on the display.
A device that is wired into accessory terminal PUSH2 is making a connection to the COM
terminal.
The gate opener is a single gate and the number 2 dip switch is in the up position.
Continue on next page.