Instruction Manual

8. Equipment Communication
+
+
+
-
-
NC
NO
GND
COM
SEN
+
+
-
-
FR1 07
FR1 07
-
PC
PC
LED
1
2
3
4
5
485+
485 -
G ND
485+
485+
485+
485-
485-
485-
G ND
G ND
G ND
NO Lock
LOCK
LOCK
Enlarged diagram
of lock ter min als
NC Lock
Lock P ower
Diode
Diode
Jumper
term inal
1. TCP/IP Communication
2. RS485 Communication
The PC software can communicate with the panel according to the communication protocols (RS485 and TCP/IP) for data
exchange and remote management. The communication cable should be as far away from high-voltage lines as possible.
Do not keep the communication cable parallel to power cords or bind them together.
Switch
8# Control Panel
Serial Bus
1# Control Panel
2# Control Panel
48 5
Converter
DIP Swi tch
8# Control Panel
2# Control Panel
1# Control Panel
1) Internationally accepted RVVP (shielded twisted-pair) wires should be used for communication to effectively avoid inter
- of bus cascade connection. ference. RS485 communication wires should be connected by means
3) One RS485 bus may hold 63 control panels, but it is recommended to connect with less than 32 .access control panels
4) For the inBIO reader connection, if the reader and the control panel use the same power, it is recommended that the wire
5) when the wire is long
er than 300 meters, it is necessary to keep To enhance the stability of communication number
2)It is recommended that the RS485 bus should be less than 600 meters to aid communication stability.
of the two devices to the system. As shown in the figure above, turn number 8 of the DIP switches of the 1# and 8#
8 switch of the first and the last control panel at “ON” status. That adds the RS485 terminal resistance
(120 ohm)
should be less than 100 meters. If greater length is required, please use a separate power supply.
EXT
R
S
4
85
PC
RS4
85
S
TAT
E
PWR
R
EADER
2R
EADER
1
SWITCH
OUT
ACT
EXT
R
S485
PC
RS485
STATE
PWR
RE
A
DE
R2R
EA
DE
R1
SWI
T
CH
OUT
ACT
E
XT
R
S
485
PC
R
S485
STA
T
E
PWR
RE
A
DER2
RE
AD
E
R1
SWI
T
C
H
OUT
ACT
EXT
RS4
8
5
P
C
RS4
8
5
S
T
ATE
PWR
READER2REA DE
R1
S
W
ITC
H
O
UT
ACT
EX
T
R
S485
PC
R
S4
85
ST
ATE
PWR
READER
2
READER1
SW
ITC
H
OUT
ACT
EX
T
RS485
PC
R
S485
ST
ATE
PWR
RE
A
DER2R
E
ADER1
SW
I
T
C
H
O
U
T
ACT
1 2 3 4
O
5 6 7 8
N
Insert a screw driver to the rectangular hole in the four corner of the panel back, push it in until hearing the “click
sound. Then remove the case from the panel. The following is wet m ode” lock connection with external power supply.
7. 485 Reader (inBIO Reader) Connection
at "ON” status.
The control panel supports inBIO biometric verification reader and Wiegand reader. All inBIO reader operations are executed
For reader 1, 2 (the odd number is for entrance reader, and the even number is for exit reader), the door number is 1. And the
485 address is 1, 2, as in the figure below. For more information, please refer to the software user manual.
from the control panel including storage, verification, etc. Re-register the fingerprints is not required when replacing the reader.
For example, use the FR1200 reader , the standby current is less than 100mA, the max current is less than 120mA, When
separately power supplies, to make sure the steady operation.
Besides, a single EXT485 interface can supply maximum 500m A(1 2V) current . So the entire cuttent consumption
should be less than this max value when the readers share power with the panel.
In calculation, more than twice of the normalplease use max current of the reader, and start current is usually
work current, please consider of this situation.
inBIO r eader connection: First of all, set the 485 address (device number) of the reader by DIP switch and software.
Attention: DIP switch configuration for FR1200, KR500E&M-RS; Software configuration for unnormalized F11,MA300 and other fingerprint readers.
the device is start, Instantaneous current can reach 240 mA. As inBIO reader, consider the starting current is
bigger, onnectthrough the EXT485 interface can only c two readers for power supply. So the power of control
panel connect only For some of the devices with much greater consumption, we suggest to using the 2 readers.
#1 Reade r
#2 Reade r
PC
STATE
PWR
E
X
T
RS4
8
5
P
C
RS
48
5
SWITCH