Service manual

BEST ACCESS SYSTEMS
Indianapolis, Indiana
T61918/Rev B 1777831 ER-7991-1
2 Insert the control key into the core and
rotate the key 15 degrees to the right.
3 Insert the core and throw member into the
knob or lever with the control key.
4 Rotate the control key 15 degrees to the
left and withdraw the key.
Note: Be sure to insert the correct throw
member into the core: six-pin cores require
the number “6” throw member; seven-pin
cores require the number “7” throw member.
Caution: The control key can be used to
remove cores and access doors. Provide
adequate security for the control key.
15 Test lock
To test the lock for proper operation, use the
temporary operator card or personal identifi-
cation number (PIN) that came with the lock.
This card or PIN is for temporary use only and
once permanent cards or PINs have been pro-
grammed for the lock, you should delete the
temporary cards or PINs.
These temporary operator cards and PINs will
only work on factory default V Series locks.
For details on programming the lock for
access control, refer to the V Series Intelligent
Programming Software User Manual or the
V Series Handheld Terminal User Manual.
For magnetic stripe card electronic locks
1 With the temporary operating instructions
facing toward you, insert and remove the
temporary operator card, as shown in
Figure 19.
The green light flashes and the locking
mechanism unlocks.
2 Turn the lever or knob and open the door.
3 Insert and turn the key to unlatch the door.
For keypad electronic locks
1 Enter the temporary operator PIN 99998
on the keypad.
2 Press
.
The green light flashes and the locking
mechanism unlocks.
3 Turn the lever or knob and open the door.
4 Insert and turn the key to unlatch the door.
For proximity card electronic locks
1 Place the temporary operator card in front
of the proximity reader, as shown in
Figure 20.
The green light flashes and the locking
mechanism unlocks
2 Turn the lever or knob and open the door.
3 Insert and turn the key to unlatch the door.
If the mechanism doesn’t unlock, refer to
the following table.
Figure 18
Figure 19
B
E
S
T
Temporary
operator card
Figure 20
LEDs Sounder Access You should…
1 long
tone
Denied Use the token at
a moderate
speed.
Green
stays
on
Denied Use the tempo-
rary operator
token, not the
temporary com-
munication
token.
Green
flashes
Denied Connect the
motor wires.
Denied Connect the
battery and con-
nect the out-
side wire
harness.
Temporary
operator card
Proximity
reader
4