Service manual

Troubleshooting
3–2 V Series Service Manual
5. Locate the DIP switches on the circuit board in the inside trim and
move switch 2 to the ON position.
6. Move switch 1 to the ON position. Both switches should now be in
the ON position.
7. Move both switches back to the OFF position. It does not matter
which switch you move first.
Caution
This function only enables communication and should be used only
when you either forget your password or lose your communication
token. The security device will not work until you return both
switches to the OFF position.
8. When you’ve finished communications and exited communication
mode, disconnect the outside wire harness from the circuit board
and reassemble the inside and outside trim on the door. For more
instructions, see To reinstall the inside and outside trim: on
page 2-39.
How do you
open a lock
after a
complete
battery failure?
If you were not able to replace the batteries before they expired and
cannot unlock the door, don’t worry! If the lock does not have a key
override feature, you still can unlock the door and access the lock’s
battery compartment.
Note: The low battery alarm may have to be cancelled. To do this, use
the terminal mode in the IPS software, or connect the handheld
terminal, and follow the prompts.
Figure 3.1 Enabling communications using the DIP switches
1
2
O
N
O
N
DIP switches