Service manual

Security Device Maintenance
2–40 V Series Service Manual
Caution
Disconnecting the inside wire harness will cause all security device
information to be lost and revert the security device to its factory
default settings. You must reprogram the security device after
disconnecting the inside cable harness.
8. Disconnect the inside wire harness from the circuit board in the
inside trim.
9. Wait at least 30 seconds, then connect the new inside wire harness
to the circuit board in the inside trim.
Note: The pair of connectors is keyed to connect only one way.
10. Slide the motor and deadbolt sensing wires into the wire clamp on
the inside trim.
11. Fasten the coin–cell battery to the inside trim.
12. Connect the motor connector and deadbolt sensing connector
(30HV only).
Note: It is possible to plug the battery pack into the motor connector
and the motor wire into the battery connector. To avoid this,
connect only the connectors with matching wire colors.
13. Position the inside trim against the door and pull the outside wire
harness back through to the outside of the door until the wire
harness is taught.
14. Making sure that the trim does not pinch the wires, secure the
inside and outside trim to the door from the inside. Use the
combination mounting screw in the top mounting hole and the
standard screw in the bottom mounting hole. Tighten the screws
firmly.
15. Position the battery pack in the battery compartment.
16. Reconnect the battery pack.
17. Insert the tabs on the lower edge of the battery compartment door
into the battery compartment. Swing the door closed. Install the
security screw.
18. Use the temporary communication token to enter the programming
mode.
19. Reprogram the security device. See the V Series Handheld
Terminal User Manual or the V Series Intelligent Programmer
Software User Manual for more information.