! Keypad Configuration
Voltage Selection
The factory default setting for the Keypad voltage is 12-24VDC.
Verify that the jumper is removed or placed over only one pin. For
5VDC, the jumper should be placed across both pins. If changing
the voltage is necessary, make sure the power is removed first.
Keypad Output Selection
Once the voltage jumper is verified or correctly set:
1. Remove power.
2. Jumper the two pins above the connector labeled "CONFIG.”
3. Apply appropriate power. (You should hear 4 beeps and the
RED LED will flash and the GREEN LED will be solid.)
4. Now that the Keypad is in configuration mode, select the
desired output by entering the configuration number followed
by #.
a. Keypad Output
Keypad Output Configuration Site Code
26 Bit Wiegand (default) 1 # 000
8 Bit Word 2 #
BCD 3 #
Serial ASCII 4 #
ABA Track II Clock & Data 5 #
4 Bit Word 6 #
Self-contained- ERM-3* 98 #
Self-contained- Non-encoded 99 #
*Requires Essex Encoded Relay Module, which contains a serial
interface to connect a computer for programming and reading
codes, or a printer for real-time print-out of activities. Refer to the
manual for the “K1-ERM Encoded Keyless Entry® Access Control
System.”